202
Tab.99 - 21200 MHz ÷ 23600 MHz band - ITU-R F.637-3 - Annex 3 and CEPT T/R 13-02 -
Go-return 1008 MHz - Frequency carrier limits
FREQUENCY RANGE: 22000 ÷ 23600 MHz - GO-RETURN: 1008 MHz - 336 MHz RF Filter Tuning Range
SUB BAND 1
Channel
bandwidth
[MHz]
Lower half of the band
Higher half of the band
Lowest Frequency
Carrier [MHz]
Highest Frequency
Carrier [MHz]
Lowest Frequency
Carrier [MHz]
Highest Frequency
Carrier [MHz]
7
22006.25
22335.25
23014.25
23343.25
14
22009.75
22331.75
23017.75
23339.75
28
22016.75
22324.75
23024.75
23332.75
56
22030.75
22310.75
23038.75
23318.75
SUB BAND 2
Channel
bandwidth
[MHz]
Lower half of the band
Higher half of the band
Lowest Frequency
Carrier [MHz]
Highest Frequency
Carrier [MHz]
Lowest Frequency
Carrier [MHz]
Highest Frequency
Carrier [MHz]
7
22258.25
22587.25
23266.25
23595.25
14
22261.75
22583.75
23269.75
23591.75
28
22268.75
22576.75
23276.75
23584.75
56
22282.75
22562.75
23290.75
23570.75
Содержание ALFOplus
Страница 1: ...ALFOplus Access Link Full Outdoor User Manual MN 00273 E 004 ...
Страница 16: ...14 MN 00273 E 004 ...
Страница 22: ...20 MN 00273 E 004 Fig 6 ALFOplus front side view 254 mm 254 mm 157 mm ...
Страница 86: ...84 MN 00273 E 004 ...
Страница 97: ...MN 00273 E 004 95 Fig 34 ODU with standard coupling kit O ring Coupling kit ...
Страница 98: ...96 MN 00273 E 004 Fig 35 1 0 ODU installation 3 1 2 ...
Страница 99: ...MN 00273 E 004 97 Fig 36 Polarization disk Reference ...
Страница 100: ...98 MN 00273 E 004 Fig 37 1 1 ODU installation 3 1 2 ...
Страница 101: ...MN 00273 E 004 99 Fig 38 1 0 antenna flange 4 3 4 1 2 5 114 60 ...
Страница 102: ...100 MN 00273 E 004 Fig 39 1 1 antenna flange 3 1 2 4 7 5 6 ...
Страница 109: ...MN 00273 E 004 107 Fig 49 Bend strain relief to lay along cable Crimp plug and strain relief ...
Страница 112: ...110 MN 00273 E 004 Fig 53 PO0032 ...
Страница 113: ...MN 00273 E 004 111 Fig 54 Connector positions Warning Tighten all unused connectors with the appropriate cover OK NO ...
Страница 118: ...116 MN 00273 E 004 Fig 58 ALFOplus connectors Fig 59 SFP LC LC Fig 60 SFP LC OPEN END ...
Страница 119: ...MN 00273 E 004 117 Fig 61 SFP LC SFP LC Fig 62 LC connector Fig 63 SFP into ALFOplus ...
Страница 120: ...118 MN 00273 E 004 Fig 64 Locked connection Fig 65 Unplug SFP ...
Страница 123: ...MN 00273 E 004 121 Fig 66 IP address setting Fig 67 Local area connection ...
Страница 144: ...142 MN 00273 E 004 Fig 82 Event log window ...
Страница 150: ...148 MN 00273 E 004 ...
Страница 220: ...218 MN 00273 E 004 ...
Страница 224: ...222 MN 00273 E 004 ...
Страница 230: ...228 MN 00273 E 004 ...