1.    NOTES ON SAFETY 

 

ƒ

 

Installation, mounting or works on the electrical connection may 
only be carried out by an approved electrician. 

ƒ

  Do not cover the product - provide free air circulation! 

ƒ

  Do not hang or fasten anything on the product, especially no 

decoration. 

ƒ

  Keep children away from the product. 

ƒ

  The fixture may only be operated with a complete and intact 

protection glass. 

ƒ

 

Operate the product only when it functions properly: 

 

 

In case of a 

malfunction

 you may 

NOT

 touch the product or operate it 

further. Disconnect the product from the power supply by an external 
switch or by the fuse. 

ƒ

  If touched or further operated there is 

danger from electric shock, 

burning, or fire.

  

malfunction

 exists when: 

ƒ

  visible damages appear. 

ƒ

  the product does not work properly (e.g. flickering). 

ƒ

  smoke, steam or crackling sounds appear. 

ƒ

  smell of burning is recognisable. 

ƒ

  an overheating is recognisable (e.g. by discolouration of adjacent 

surfaces). 

Operate the product only after maintenance and examination by an 

approved electrician! 

 

2.    USE AS DIRECTED 

 

This product serves exclusively lighting purposes and may: 

ƒ

  only be used with a voltage of 

230V ~50Hz

ƒ

  only be operated when firmly mounted. 

ƒ

  not be exposed to strong mechanical loads or to strong 

contamination. 

ƒ

  only be installed and operated after a condition inspection if the 

product is dirty or has been moistened through storage. 

ƒ

  not be modified or converted. 

 

3.    OPERATION 

 

 

 

There may be hot surfaces on the fixture. These surfaces are 
indicated on the drawing or on the fixture by the following sign:  
Exchange the light source always before it reaches its lifespan, to avoid 
personal injuries, or damages of the fixture or other objects. 

Disconnect the product from the power supply

, before you exchange 

the bulbs. Let the 

light source cool down

 before replacement.

 

ƒ

  There exists danger of burning! 

Use only light sources that are approved for the product. Approved light 
sources are indicated on the type label. 

ƒ

  Other types of light sources may cause 

fire risk

damage the product

 

or

 lead to malfunction

ƒ

 

Replacing the light source:

 Remove the shield and the protection 

glass by loosening the screws. Remove the used bulb. Insert the bulb 
applying a slight turn to the right. Reattach the shield and the glass. 

ƒ

  Check and clean the gasket after each opening of the fixture. The 

bearing surface of the gasket must be free of dirt. These measures 
ensure that the IP class is maintained.

 

ƒ

  Note the proper fit for the gasket. Tighten the screws in a cross-wise 

order, to achieve an even pressure on the gasket.

 

 

4.    MAINTANANCE AND CARE 

 
The following enviromental influences may have unwanted effects on 
the surface of the product: 

ƒ

  acid rain and sour soil 

ƒ

  high salt content in the air 

ƒ

 thawing salt 

ƒ

 cleaning 

agents 

ƒ

  fertilizer especially in flowerbeds 

ƒ

  other chemical substances (e.g. herbicides) 

Protect the product by adequate means to avoid unwanted changes of the 
surface. 

 

 

Disconnect the product from the power supply 

and let it

 cool down

before you clean the product. 

ƒ

  If disregarded there may be 

danger of electric shock 

or by 

burning 

when cleaning the product. 

ƒ

 

Cleaning: 

Clean the product on a regular basis using a slightly 

moistened, soft and fluff-free cloth. Please also note additional supplied 
notes on maintanance and care. 

 

5.    ADDITIONAL IMPORTANT NOTES 

 
Storage:

 The product must be stored in a dry and clean environment. Do 

not strain the product mechanically during storage. 

Warranty: 

In case of a warranty contact your dealer.

 

Disposal: 

Notes on the correct disposal in Germany are found on 

www.slv.de. 
 

6.   INSTALLATION 

(only by an approved electrician)

 

 

 

Switch off the mains 

or respectively the connection lead before doing 

any works.  

ƒ

 There 

exists 

mortal danger from an electric shock

Use only parts, which are supplied with the product or are described as 

accessories

ƒ

  Otherwise the product or the whole installation may not be secure. 

Danger for life or danger of fire may exist!

 

Inspect the product for 

loose parts

 inside the housing. When there are 

loose parts inside the housing and these are not explicitly described the 
product may not be installed or operated. 

ƒ

  The housing maybe voltage-carrying.

 Danger of electric shock!

 

 
Unpacking 

ƒ

 

Consignment: 

Three protective tubes 

Installation pot 

ƒ

  Carefully take the product out of the packaging removing any transport 

safeguards. 

ƒ

  Before disposal of the packaging material make sure that all 

components of the product are removed. 

 
Installation place 

ƒ

  The product is solely suited for 

recessed floor installation

ƒ

  Make sure that the product is mounted on a 

stable, even and tilt-fixed 

background

ƒ

 The 

light exit

 should be placed at least so far from the illuminated 

surface, as indicated as 

minimum distance

 on the type plate of the 

luminaire: 

Pay special caution

 to easily inflammable objects 

(e.g. foliage). 

 
Before installation 

ƒ

  Do not try to seal the product yourself, using additional silicon or another 

sealant. 

ƒ

 DO 

NOT

 REMOVE THE GREASE ON THE SCREWS AND THE 

SCREW HOLES! The grease inhibits anodic corrosion (electrolysis). 
Renew the grease on the screw connections after each time the fixture 
has been opened.  

ƒ

  Carry out the installation when the weather is dry. 

ƒ

  Prepare the recess if not done yet. When installing the lighting unit 

outdoors provide a gravel bed, 20 cm thick, beneath the installation pot. 
This serves as protection from corrosion. 

ƒ

  Prepare the power supply lead according to valid rules for outdoor 

installations.

 

Separate Installation Steps 

ƒ

  Remove the shield by loosening the screws.

 

ƒ

  Take the fixture out of the plastic casing. 

ƒ

  Direct the earth cable through the opening of the plastic casing. 

ƒ

  Fix the plastic casing firmly into the earth. 

ƒ

  Remove the connection plate(a) and the bulb holder(b). 

ƒ

  Direct the earth cable, in sufficient length, through the cable screwing. 

ƒ

  Secure the cable screwing using a suitable tool. 

ƒ

 

Electrical Connection 

ƒ

  The product must be able to be separated by an all pole separation 

from the current supply. 

ƒ

  Equip the three wire ends with protective tubes. 

ƒ

  For electric connection attach the black or brown wire (live conductor) 

of the mains supply with the clamp L and the blue wire (neutral 
conductor) of the mains supply with the clamp N. The green-yellow 
wire (protective conductor) of the mains supply has to be tightly 

screwed into the earth clamp 

 of the product. 

ƒ

  Fix the connection plate and the bulb holder again. 

ƒ

 

Inserting the bulb:

 Insert the bulb applying a slight turn to the right. You 

may adjust the position of the bulb now.

 

ƒ

  Assemble the fixture in reverse order. Pay attention that the gasket fits 

properly. The bearing surface of the gasket must be free of dirt. Tighten 
the screws on the shield in a cross-wise order, to achieve an even 
pressure on the gasket.

 

ƒ

  The product is now ready for operation. 

 
 

art.-no.  228430/34   
12/2009 

© SLV Elektronik GmbH, Daimlerstr. 21-23, 52531 Übach-

Palenberg, Germany, Tel. +49 (0)2451 4833-0 
Technical Details are subject to change.

 

 

SLV Elektronik GmbH 
ENGLISH

 

INSTRUCTION MANUAL FOR 
RECESSED GROUND FITTING 

DASAR EXACT GU10 

Содержание DASAR EXACT GU10

Страница 1: ...gen van stof Bescherming tegen het indringen van water bij tijdelijke onderdompeling Beskyttelse mod indtrængning av støv Beskyttelse mod indtrængning av vand hvis genstanden bliver foreløbigt dykket ned art no 228430 34 12 2009 Technische Änderungen vorbehalten Technical Details are subject to change Les détails techniques sont sujet à des changements Nos reservamos el derecho a modificaciones té...

Страница 2: ...stungen geschützt gelagert werden Garantie Im Garantiefall wenden Sie sich bitte an Ihren Fachhändler Entsorgung Hinweise zur ordnungsgemäßen Entsorgung finden Sie im Internet unter www slv de oder unter der unten angegebenen Telefonnummer 6 MONTAGE nur durch zugelassene Elektrofachkraft Schalten Sie die Stromversorgung bzw die Anschlussleitung spannungsfrei bevor Sie jegliche Arbeiten vornehmen E...

Страница 3: ...product mechanically during storage Warranty In case of a warranty contact your dealer Disposal Notes on the correct disposal in Germany are found on www slv de 6 INSTALLATION only by an approved electrician Switch off the mains or respectively the connection lead before doing any works There exists mortal danger from an electric shock Use only parts which are supplied with the product or are desc...

Страница 4: ...t être stocké dans un lieu sec à l abrie de saleté salissure et de toute charge mécanique Garantie Dans le cas d une réclamation de garantie veillez vous adresser à votre marchant spécialisé Retraitement Vous trouverez les indications nécessaires pour un retraitement réglementaire sur internet www slv de ou bien sous le numéro de Téléphone indiqué ci dessous 6 INSTALLATION seulement par un électri...

Страница 5: ...te nuestra página Internet bajo www slv de o llame el número de teléfono abajo indicado 6 MONTAJE sólo por un electricista homologado Antes de empezar con cualquier tipo de trabajo desconecte la fuente de alimentación resp el cable de alimentación Hay peligro de muerte por electrocución Utilice solamente partes suministradas junto con el producto o partes que son descritas de forma explícita como ...

Страница 6: ...anti lo smaltimento corretto si ritrovano sul sito www slv de o si possono richiedere telefonicamente al numero di telefono indicato a seguito 6 MONTAGGIO solo ad opera di un esperto elettrotecnico Tolga la tensione dall approvvigionamento della corrente ovvero del condotto di collegamento prima di eseguire un lavoro Vi è il pericolo di scossa elettrica che potrebbe causare la morte Impieghi unica...

Страница 7: ...n garantie wendt u zich tot uw handelaar Afvalverwerking Verwijzingen m b t adequate afvalverwerking vindt u op internet onder www slv de of onder het beneden aangegeven telefoonnummer 6 MONTAGE slechts door een erkend vakman electricien Stroomvoorziening aansluitingsleiding spanningsvrij schakelen voordat enig werk uit wordt gevoerd Er bestaat gevaar van elektrische schok met de dood ten gevolge ...

Страница 8: ...inger til reglementeret bortskaffelse i Internettet under www slv de eller under telefonnummeret som er angivet nedenfor 6 MONTAGE udelukkende af en autoriseret elektriker Før du gører noget arbejde omkobler strømforsyningen og den forbindende fører spændingsfri Der er faren af et elektriskt slag med dødfølge Brug kun denne dele som er blevet leveret sammen med produktet eller som er beskrevede en...

Отзывы: