Hydraulic Installation
Fin Valve Unit
The Fin valve unit should be located as close as possible(Recommended < 2,5m (max 3,5m)), to the Actuator Valve Unit with recommended hose
dimensions (System drawings). Use a minimum 2 layer steel braided hoses.
If the fi n valve unit is installed more than 2,5m from the actuator, very stiff (none expanding) hoses or even better, some of the distance in rigid piping
is necessary to not make the fi n movement “soft” by the hoses expanding with varying pressure. Always fi t hoses to the hull on soft mounts.
The unit must be mounted on a rigid flat surface - and we recommend to use a vibration dampening material behind them to avoid any high-frequency
noise/vibration to go into the structure of the boat.
MC_0217
MG_0225
IMPORTANT
The unit must be mounted on a
rigid flat surface
MG_0226
Locking valve
Proportional valves
Test ports
Lock nut
Allen key
P: Pressure from accumulator
T: Tank return