Reg Address
Bit Field
Type
Setting Name
Description
0x0104
5:4
R/W
OUT0A_DIS_STAT
E
Determines the state of an output driver when disabled,
selectable as:
0: Disable in low state
1: Disable in high state
2: Reserved
3: Reserved
0x0104
7:6
R/W
OUT0A_CMOS_DR
V
LVCMOS output impedance. See
Settings for LVPECL, LVDS, HCSL, and CML
See
8.3 Performance Guidelines for Outputs
Table 15.42. 0x0105 Clock Output 0A Amplitude and Common Mode Voltage
Reg Address
Bit Field
Type
Setting Name
Description
0x0105
3:0
R/W
OUT0A_CM
This field only applies when OUT0A_FORMAT=1 or 2.
See
8.4.8 Output Driver Settings for LVPECL, LVDS,
and
8.4.9 Setting the Differential Out-
put Driver to Non-Standard Amplitudes
for details of the
settings.
0x0105
6:4
R/W
OUT0A_AMPL
This field only applies when OUT0A_FORMAT=1 or 2.
See
8.4.8 Output Driver Settings for LVPECL, LVDS,
and
8.4.9 Setting the Differential Out-
put Driver to Non-Standard Amplitudes
for details of the
settings.
ClockBuilder Pro sets the correct common mode voltage and amplitude for LVDS, LVPECL, and HCSL outputs.
Table 15.43. 0x0106 Clock Output 0A Mux and Inversion
Reg Address
Bit Field
Type
Setting Name
Description
0x0106
2:0
R/W
OUT0A_MUX_SEL OUT0A output source divider select. This selects the
multisynth (N divider) that is connected to the output
driver.
0: N0
1: N1
2: N2
3: N3
4: N4
5-7: Reserved
0x0106
3
R/W
OUT0A_VDD_SEL_
EN
Output Driver VDD Select Enable. Set to 1
for normal operation.
Si5391 Reference Manual • Si5391A/B Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
74
Rev. 0.5 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 11, 2022
74