Table 2.2. Only Domain 1 and 2 Output Frequencies
Output Clock Frequencies
Output Clock Location allowed?
0A
0
1
2
3
4
5
6
7
8
9
9A
125/156.25/312/625
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
25/125/200
no
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
50/100
no
no
no
no
yes
yes
yes
yes
yes
yes
yes
yes
Table 2.3. Domain 1, 2, and 3 Output Frequencies
Output Clock Frequencies
Output Clock Location allowed?
0A
0
1
2
3
4
5
6
7
8
9
9A
125/156.25/312/625
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
no
25/125/200
no
no
no
yes
yes
yes
yes
yes
yes
yes
yes
yes
50/100
no
no
no
no
yes
yes
yes
yes
yes
yes
yes
yes
322.265625/644.53125
no
no
no
no
no
no
no
no
yes
yes
yes
yes
Table 2.4. Only Domain 1 and 3 Output Frequencies
Output Clock Frequencies
Output Clock Location allowed?
0A
0
1
2
3
4
5
6
7
8
9
9A
156.25/312/625
yes
yes
yes
yes
no
no
no
no
no
no
no
no
125
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
322.265625/644.53125
no
no
no
no
no
no
no
no
yes
yes
yes
yes
156.25MHz/312.5MHz/625MHz Separation Rules to Domain 2 and 3 Clocks:
Even though the Si5391P has minimal coupling between adjacent clocks, a domain 2 or 3 clock that is adjacent to 156.25/312.5/625
MHz may couple too much energy to allow these Domain 1 clocks to meet <100 fs clocks. Therefore domain 2 and 3 clocks must be
isolated from 156.25/312.5/625 MHz outputs. In addition to the tables above, ClockBuilder Pro enforces gaps between domain 1 and
domain 2 outputs. ClockBuilder Pro makes it simple to achieve 156.25/312.5/625 MHz outputs that are guaranteed to have <100 fs rms
jitter. Only when the output clock locations meet all the rules, ClockBuilder Pro will classify a 156.25/312.5/625 MHz output as being
"precision" and guaranteed to achieve <100fs rms jitter.
2.2.3 Output Clock Format Restrictions
For the 156.25/312.5/625 MHz clocks to achieve < 100 fs jitter there are restrictions on the output formats as follows:
1. 156.25/312.5/625 MHz clocks can only be LVPECL or LVDS.
2. Domain 2 outputs can only be LVPECL, LVDS or HCSL.
3. Domain 3 outputs can only be LVPECL or LVDS.
4. If any domain 2 or 3 output is LVPECL or HCSL, then 156.25/312.5/625 MHz outputs must be LVPECL.
Si5391 Reference Manual • Family Product Comparison
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
7
Rev. 0.5 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 11, 2022
7