7.3 Fault Monitoring
The Si5391 provides fault indicators which monitor loss of signal (LOS) of the inputs (IN0, IN1, IN2, XA/XB, FB_IN) and loss of lock
(LOL) for the PLL, as shown in the diagram below. These fault conditions, as well as other internal status indications, are provided
through a combination of internal registers and externally provided signals (LOLb and INTRb). Usage and configuration of status/fault
monitoring features, as well as mapping these to the INTRb output, are described on following sub sections.