Register field name
Address Base
Bit
length
R/W/RW
Description
Device
mode
HSDIV1_DIV_SEL
35
1
1
RW
Selects bank A (0) or bank B (1) O1 divid-
er settings. Same description applies as
for HSDIV0_DIV_SEL.
READY/
ACTIVE
ID0A_INTG
36
0
15
RW
The terms of an a + b/c desired di-
vider setting must be processsed into
ID0A_INTG, ID0A_RES, and ID0A_DEN
register terms.intg = floor(((a*c+b)*128/c) -
512).
READY
if divider
is cur-
rently
driving
the out-
put else
READY/
ACTIVE
ID0A_RES
38
0
15
RW
res = mod(b*128, c)
ID0A_DEN
3A
0
15
RW
den = c
ID0A_SS_ENA
3C
0
1
RW
Spread spectrum enable. This is the on-
ly bank configuration field which may be
changed dynamically while the bank is
selected as the active bank. Users may
freely enable/disable spread spectrum. 0
= spread spectrum disabled 1 = spread
spectrum enabled
ID0A_SS_MODE
3C
1
2
RW
Spread spectrum mode. 0 = disabled 1 =
center 2 = invalid 3 = Down
ID0A_SS_STEP_NUM
3D
0
12
RW
Number of frequency steps in one quad-
rate, allows for frequency step every out-
put clock.
ID0A_SS_STEP_INTG
3F
0
12
RW
Divide ratio spread step size.
ID0A_SS_STEP_RES
40
0
15
RW
Numerator of spread step size error term.
ID0B_INTG
42
0
15
RW
The terms of an a + b/c desired di-
vider setting must be processsed into
ID0B_INTG, ID0B_RES, and ID0B_DEN
register terms.intg = floor(((a*c+b)*128/c) -
512).
READY
if divider
is cur-
rently
driving
the out-
put else
READY/
ACTIVE
ID0B_RES
44
0
15
RW
res = mod(b*128, c)
ID0B_DEN
46
0
15
RW
den = c
ID0B_SS_ENA
48
0
1
RW
Spread spectrum enable. This is the on-
ly bank configuration field which may be
changed dynamically while the bank is
selected as the active bank. Users may
freely enable/disable spread spectrum. 0
= spread spectrum disabled 1 = spread
spectrum enabled
ID0B_SS_MODE
48
1
2
RW
Spread spectrum mode. 0 = disabled 1 =
center 2 = invalid 3 = Down
ID0B_SS_STEP_NUM
49
0
12
RW
Number of frequency steps in one quad-
rate, allows for frequency step every out-
put clock.
ID0B_SS_STEP_INTG
4B
0
12
RW
Divide ratio spread step size.
ID0B_SS_STEP_RES
4C
0
15
RW
Numerator of spread step size error term.
Si5357 Reference Manual • Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
28
Rev. 0.2 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 26, 2021
28