14.2.4 Page 3 Registers Si5341
Table 14.69. 0x0302–0x0307 N0 Numerator
Reg Address
Bit Field
Type
Setting Name
Description
0x0302
7:0
R/W
N0_NUM
44-bit Integer Number
0x0303
15:8
R/W
N0_NUM
0x0304
23:16
R/W
N0_NUM
0x0305
31:24
R/W
N0_NUM
0x0306
39:32
R/W
N0_NUM
0x0307
43:40
R/W
N0_NUM
The N dividers are interpolative dividers that are used as output dividers that feed into the R dividers. ClockBuilder Pro calculates the
correct values for the N-dividers.
Table 14.70. 0x0308–0x030B N0 Denominator
Reg Address
Bit Field
Type
Setting Name
Description
0x0308
7:0
R/W
N0_DEN
32-bit Integer Number
0x0309
15:8
R/W
N0_DEN
0x030A
23:16
R/W
N0_DEN
0x030B
31:24
R/W
N0_DEN
Table 14.71. 0x030C N0 Divider Update Bit
Reg Address
Bit Field
Type
Setting Name
Description
0x030C
0
S
N0_UPDATE
Must write a 1 to this bit to cause N0 divider changes to
take effect.
Table 14.72. N1, N2, N3 Numerator and Denominators
Register Address
Setting Name
Size
Same as Address
0x030D-0x0312
N1_NUM
44-bit Integer Number
0x0302-0x0307
0x0313-0x0316
N1_DEN
32-bit Integer Number
0x0308-0x030B
0x0318-0x031D
N2_NUM
44-bit Integer Number
0x0302-0x0307
0x031E-0x0321
N2_DEN
32-bit Integer Number
0x0308-0x030B
0x0323-0x0328
N3_NUM
44-bit Integer Number
0x0302-0x0307
0x0329-0x032C
N3_DEN
32-bit Integer Number
0x0308-0x030B
0x032E-0x0333
N4_NUM
44-bit Integer Number
0x0302-0x0307
0x0334-0x0337
N4_DEN
32-bit Integer Number
0x0308-0x030B
Si5341, Si5340 Rev D Family Reference Manual • Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
79
Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 26, 2021
79