Table 14.175. 0x094A Input Clock Routing Enable
Reg Address
Bit Field
Type
Setting Name
Description
0x094A
6:4
R/W
INx_TO_PFD_EN
When = 1, enables the routing of the 3 input clocks
IN0,1,2 to the Phase Detector. Each bit corresponds
to the inputs as follows [6:4] = [IN2 IN1 IN0]. IN_SEL
is used to select the input clock that is applied to the
phase detector.
Table 14.176. 0x095E
Reg Address
Bit Field
Type
Setting Name
Description
0x095E
0
R/W
M_INTEGER
Set by CBPro
14.3.6 Page A Registers Si5340
Table 14.177. 0x0A03 N Divider Clocks
Reg Address
Bit Field
Type
Name
Description
0x0A03
3:0
R/W
N_CLK_TO_OUTX_EN
Bits in this field correspond to the N dividers as [N3 N2
N1 N0]. If an N divider is used, the corresponding bit
must be 1. See also registers 0x0A05 and 0x0B4A[3:0]
Table 14.178. 0x0A04 N Divider Phase Interpolator Bypass
Reg Address
Bit Field
Type
Name
Description
0x0A04
3:0
R/W
N_PIBYP
Bypasses the Phase Interpolator of the N Multisynth di-
vider. Set to a 1 when the value of N divider is integer
and will not be used as a DCO. Set to a 0 when the
value of N is fractional (used as a DCO). Slightly lower
output jitter may occur when the Phase Interpolator is
bypassed (=1). Bits in this field correspond to the N
dividers as [N3 N2 N1 N0]
A soft reset reg 0x001C [0] should be asserted after changing any of these bits. If it is expected that any of the N dividers will
be changing from integer to fractional, it is recommended that the corresponding bits be initialized to 0 so that when the change
from integer to fractional occurs there will be no need for a soft reset. For this reason DCO (digitally controlled oscillator) and FOTF
(frequency on the fly) applications should have zeros for these bits. See
DCO Applications with Jitter Attenuators
.
Table 14.179. 0x0A05 N Divider Power Down
Reg Address
Bit Field
Type
Name
Description
0x0A05
3:0
R/W
N_PDNB
Powers down the N divider. If an N divider is not used,
set the respective bit to 0 to power it down. Bits in this
field correspond to the N dividers as [N3 N2 N1 N0].
See also registers 0x0A03 and 0x0B4A[3:0]
Si5341, Si5340 Rev D Family Reference Manual • Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
107
Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 26, 2021
107