14.3.7 Page B Registers Si5340
Table 14.180. 0x0B2E Synchronous Output Disable Timeout Value
Reg Address
Bit Field
Type
Setting Name
Description
0x0B2E
6:0
R/W
MS_OD_G_TIME-
OUT
Controls the synchronous output disable timeout value
during a hard reset.
0x0B2E
7
R/W
MS_OD_G_TIME-
OUT_EN
Table 14.181. 0x0B4A Divider Clock Disables
Reg Address
Bit Field
Type
Setting Name
Description
0x0B4A
3:0
R/W
N_CLK_DIS
Controls the clock to the N divider. If an N divider is
used the corresponding bit must be 0. [N3 N2 N1 N0].
See also registers 0x0A03 and 0x0A05.
Table 14.182. 0x0B57
Reg Address
Bit Field
Type
Name
Description
0x0B57
7:0
R/W
VCO_RESET_CAL-
CODE
12-bit value
0x0B58
11:8
R/W
VCO_RESET_CAL-
CODE
Si5341, Si5340 Rev D Family Reference Manual • Register Map
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
108
Rev. 1.3 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 26, 2021
108