30
TABLE 02
PROBLEMS
CAUSES
SOLUTIONS
- Equipment does not turn on.
- Energy supply interrupted.
-Emer
gency buon pressed.
- Problem in the equipment’s
internal or external electric
circuit.
- Verify the supply of electric
energy.
- Proceed as per item 3.
- Call qualified technical
service.
- Burn and/or smoke smell.
- Problem on internal or
external electrical circuit of the
equipment;
- Call qualified technical
service.
- The equipment turns on, but
when product is processed
in the equipment, it stops or
turns in low r
otaon.
- Problem on internal or
external electrical circuit of the
equipment;
- Call qualified technical
service.
- Damaged electrical cord.
- Damage during
product transport
aon
and/or handling
- Call qualified technical
service.
- Irregular Slicing
- Blade los
t its cung edge.
- Proceed as per item 3.2.1
- When the equipment is
turned on only the Blade spins
- The Sharpening command is
acvated..
- Proceed as per item 3.1
7
1.2 Main Components
All the components used in this equipment are made of and constructed with thoroughly
selected materials for each funcon, in accordance with test standards and Siemsen’s
experience.
PICTURE 01
01 - Feeding Cord
02 - Equip. Terminal
03 - General key
04 - Side Regulator
05 - Pusher
06 - Movable Table
07 - Regulang Handle
08 - Control Panel
09 - On/Off Key
10 - Emer
gency Buon
11 - Foot
12 - Cut Regula
ng Table
04
01
03
02
06
05
12
08
09
10
07
11