KYJACK, Page 14
JIII eries
ection 5 - Procedures
ervice and Maintenance
5.3-3 LED Error Codes - Code Breakdown Chart (Continued)
Vehicle ilted
11
Vehicle Overloaded
12
oo High - Drive Prevented
14
oo High - Lift Up Prevented
15
hese are not true faults but an indication that vehicle movement is prevented. Remove excessive load from the
platform. Lower the platform if close to maximum height. Move the vehicle to level ground.
Invalid Height - Check Sensor
65
Check the voltage out of the height transducer, into P4-3. It should be between .4V and 4.6V and should vary as
the platform position varies.
esting HWFS
78
Start Up!
77
hese are not true faults unless they do not clear – the start-up tests should only occur for a short time.
Overload Functions Disabled!
66
Factory Override
67
hese are not true faults – the GP102 has been configured to suppress overload functionality.
Idle imeout Active!
Always Off
Fault: Bad ilt Sensor
71
Fault: Bad HWFS
72
Fault: Bad Slave Analogs
73
Fault: Bad Strain Monitors
74
Fault: Bad Slave Micro
75
Fault HWFS Stalled!
76
Action a function to clear the idle timeout if it occurred. Ensure the GP102 is correctly mounted – incorrect
mounting can cause the “bad tilt sensor” diagnostic to occur. Otherwise there may be an internal problem with the
GP102.