KYJACK, Page 23
JIII eries
ection 5 - Procedures
ervice and Maintenance
39. Press EN ER to complete date entry (the system will store it).
40. he display will show “
Calibrate Load
” option.
41. Press the ESC button to exit the “
Calibrate Load
” option.
42. Remove the jumper wire and re-connect the black wire #14 to the coil removed earlier.
43. Close the hydraulic/electric tray.
NOTE
Continuing partially complete load calibration.
Once a calibration phase has been successfully completed, it is not required to do it again (unless of course
a change to the vehicle such as a replacement sensor requires that calibration be repeated). his is useful if
the calibration procedure is interrupted – the remaining phases can be completed at a later time.
If a calibration phase has been successfully completed, a “
REDO
” message is displayed:
REDO DYNAMIC: NO
REDO LOADED: NO
REDO EMPTY: NO
If the phase does not need to be repeated, just press
ENTER
to move on.
If the phase does need to be repeated, press
UP
or
DOWN
to change “
NO
” to “
YE
” then press
ENTER
.