94
SJ30AJE, SJ30ARJE
196274AF
Section 4 – Troubleshooting Information
Electrical System
8.
Loose or broken wire #36 in boom cable A or its
connectors.
Check for continuity between pins #18 on cable
A. Check for loose or corroded connections on
cable connectors. Replace if wire is defective.
9.
Loose or broken wire #36 plug A pin #18 to
platform terminal block.
Check continuity. Replace if defective.
10.
Loose or broken wire #36 from platform terminal
block to platform rotate left valve 4H-36.
Check continuity. Replace if defective.
11.
Loose or broken wire #02 from platform terminal
block to platform rotate left valve 4H-36.
Check continuity. Replace if defective.
12.
Defective platform rotate left valve coil 4H-36.
Check continuity and resistance through coil.
Replace if defective.
4.2-14 No Platform Rotate Right from Base Control Console
1.
Loose or broken wire #10A from enable switch
S21 to platform rotate switch S14.
Check continuity. Replace if defective.
2.
Defective platform rotate switch S14.
Check continuity through switch while activating
rotate right function between wires #10A and #37.
If no continuity found, replace switch.
3.
Loose or broken wire #37 from platform rotate
switch S14 to base terminal block.
Check continuity. Replace if defective.
4.
Open or defective diode D37.
Check diode. Replace if defective.
5.
Loose or broken wire #73 from base terminal
block to motor control harness A.
Check continuity. Replace if defective.
6.
Loose or broken wire #73 from motor control
harness A pin #22 to left motor controller pin
#LM32.
Check continuity. Replace if defective.
7.
Loose or broken wire #37 from base control
block to platform plug A pin #19 in base control
console.
Check continuity. Replace if defective.
8.
Loose or broken wire #37 in boom cable A or its
connectors.
Check for continuity between pins #19 on cable
A. Check for loose or corroded connections on
cable connectors. Replace if wire is defective.
9.
Loose or broken wire #37 plug A pin #19 to
platform terminal block.
Check continuity. Replace if defective.
10.
Loose or broken wire #37 from platform terminal
block to platform rotate left valve 4H-37.
Check continuity. Replace if defective.
11.
Loose or broken wire #02 from platform terminal
block to platform rotate left valve 4H-37.
Check continuity. Replace if defective.
12.
Defective platform rotate left valve coil 4H-37.
Check continuity and resistance through coil.
Replace if defective.
Содержание SJ30AJE
Страница 1: ...SERVICE MANUAL ARTICULATING BOOM 196274AF November 2018 ANSI CSA CE AS KC SJ30AJE SJ30ARJE ...
Страница 4: ...4 SJ30AJE SJ30ARJE 196274AF Notes ...
Страница 10: ...10 SJ30AJE SJ30ARJE 196274AF 5 7 1 Lubrication 188 ...
Страница 45: ...45 SJ30AJE SJ30ARJE 196274AF Section 3 System Component Identification and Schematics ...
Страница 68: ...A B C D E F G H V Z Y X W 68 SJ30AJE SJ30ARJE 196274AF ...
Страница 128: ...128 SJ30AJE SJ30ARJE 196274AF Notes ...
Страница 189: ......
Страница 190: ...www skyjack com ...