170
SJ30AJE, SJ30ARJE
196274AF
Section 5 – Procedures
Base
Flash
Code
Displayed
on
MDI
Probabable
Cause
Remedy
Cause
1:
Before
switching
the
Line
Contactor
on,
the
software
checks
the
power
bridge:
it
turns
on
alternatingly
the
Low
side
Power
Mosfets
and
expects
the
phases
voltage
to
decrease
down
to
‐
BATT.
If
the
phases
voltage
is
igher
than
10%
of
nominal
battery
voltage,
this
alarm
occurs.
Cause
2:
This
alarm
may
occur
also
when
the
start
up
diagnosis
is
overcome,
and
so
the
Line
Contactor
is
closed.
In
this
condition,
the
phases’
voltages
are
expected
to
be
lower
than
1/2
battery
voltage.
If
it
is
higher
than
that
value,
fault
status
is
entered.
Troubleshooting:
‐
If
the
problem
occurs
at
start
up
(the
Line
Contactor
does
not
close
at
all),
check:
‐
Motor
internal
connections
(ohm
internal
connections
continuity)
‐
Motor
power
cables
connections
‐
If
the
motor
connection
are
OK,
the
problem
is
inside
the
controller,
replace
Controller.
‐
If
the
problem
occurs
after
closing
the
Line
Contactor
(the
Line
Contactor
closed
and
then
opens
back
again),
check:
‐
Motor
connections
‐
Make
sure
motor
phases
windings/cables
do
not
have
leakages
towards
chassis
‐
If
no
problems
are
found
on
the
motor/
cables,
the
problem
is
inside
the
controller,
Replace
controller.
0XA40
AUX.
DRIV.SHRT.
Mos
for
electric
brake
is
shorted
1.
Cycle
keyswitch
2.
Check
for
short
or
low
‐
impedence
to
electric
brakes
3.
Replace
controller
that
shows
the
fault.
0XA41
WRONG
SET
BAT.
Controller
rejects
the
battery
voltage
reading
At
start
‐
up,
the
controller
checks
the
battery
voltage
and
verify
it
is
within
a
window
around
the
nominal
value.
Troubleshooting:
‐
Check
that
the
controller
SET
BATTERY
parameter
value
matches
the
battery
nominal
voltage.
‐
Check
that
TESTER
MENU
/
BATTERY
VOLTAGE
parameter
shows
same
value
as
the
battery
voltage
measured
with
a
voltmeter.
If
it
does
not
match,
then
do
an
“ADJUST
BATTERY”
function.
0XA42
AUX.
DRIV.OPEN.
Driver
of
electric
brake
is
damaged
(not
able
to
close)
1.
Check
wiring
between
controller
and
electric
brake
2.
Replace
electric
brakes
3.
Replace
controller
that
shows
the
fault.
0XA49
LIFT
&
LOWER
Lift
and
lower
requested
at
the
same
time.
Check
joystick
outputs.
Factory
reset
(Clear
Eeprom)
Self
check
of
Power
components
and
Motor
VMN
HIGH
0XA31
ZAPI MDI-CAN Controller Master Codes (continued)
Содержание SJ30AJE
Страница 1: ...SERVICE MANUAL ARTICULATING BOOM 196274AF November 2018 ANSI CSA CE AS KC SJ30AJE SJ30ARJE ...
Страница 4: ...4 SJ30AJE SJ30ARJE 196274AF Notes ...
Страница 10: ...10 SJ30AJE SJ30ARJE 196274AF 5 7 1 Lubrication 188 ...
Страница 45: ...45 SJ30AJE SJ30ARJE 196274AF Section 3 System Component Identification and Schematics ...
Страница 68: ...A B C D E F G H V Z Y X W 68 SJ30AJE SJ30ARJE 196274AF ...
Страница 128: ...128 SJ30AJE SJ30ARJE 196274AF Notes ...
Страница 189: ......
Страница 190: ...www skyjack com ...