171
SJ30AJE, SJ30ARJE
196274AF
Base
Section 5 – Procedures
Flash
Code
Displayed
on
MDI
Probabable
Cause
Remedy
0XA51
TILLER
OPEN
No
operator
input,
machine
in
standby
Warning
when
the
joystick
is
released,
after
a
fixed
period
of
time
of
standby
(30
seconds)
the
main
contactor
opens.
Troubleshooting:
At
the
next
function
request
the
warning
will
disappear.
0XA52
PUMP
I=0
EVER
Pump
motor
is
always
0
amps
even
when
pump
motor
is
running
1.
Check
wiring
to
Pump/
Motor
2.
Recycle
keyswitch
3.
Replace
Controller.
0XA53
STBY
I
HIGH
Internal
Controller
check
1.
Cycle
keyswitch
(If
code
remains
see
next)
Cause:
The
current
transducer
or
the
current
feedback
circuit
is
damaged
in
the
Controller
Troubleshooting:
This
type
of
fault
is
not
related
to
external
components
so,
when
it
is
present,
it
is
necessary
to
replace
the
controller
0XA53
WRONG
ZERO
The
outputs
of
the
amplfiers
(used
to
measure
motor
voltage)
are
checked.
This
alarm
occurs
when
voltage
signals
>3V
or
<2V.
1.
Cycle
keyswitch
2.
Factory
reset
(Clear
Eeprom)
3.
Replace
controller.
0XA54
LOGIC
FAIL
#1
Over
voltage/
under
voltage
condition
has
been
detected
1.
Check
battery
for
load
induced
voltage
drop.
Low
voltage
could
be
causing
an
under
voltage
condition.
Check
battery
cables.
2.
Factory
reset
(Clear
Eeprom)
3.
Replace
controller.
0XA55
LOGIC
FAIL
#2
Motor
voltage
feedback
circuits
are
damaged
1.
Cycle
keyswitch
2.
Factory
reset
(Clear
Eeprom)
3.
Replace
controller.
0XA56
PUMP
I
NO
ZERO
Pump
current
sensor
feedback
is
out
of
permitted
standby
range
1.
Cycle
keyswitch
2.
Factory
reset
(Clear
Eeprom)
3.
Replace
controller.
0XA60
CAPACITOR
CHARGE
Startup
test
1.
Check
battery
voltage
2.
Check
battery
and
motor
cables
0XA61
THERMIC
SENS.
KO
Controller
Cause:
The
output
of
the
controller
thermal
sensor
is
out
of
range.
Troubleshooting:
This
type
of
fault
is
not
related
to
external
components;
replace
the
controller.
ZAPI MDI-CAN Controller Master Codes (continued)
Содержание SJ30AJE
Страница 1: ...SERVICE MANUAL ARTICULATING BOOM 196274AF November 2018 ANSI CSA CE AS KC SJ30AJE SJ30ARJE ...
Страница 4: ...4 SJ30AJE SJ30ARJE 196274AF Notes ...
Страница 10: ...10 SJ30AJE SJ30ARJE 196274AF 5 7 1 Lubrication 188 ...
Страница 45: ...45 SJ30AJE SJ30ARJE 196274AF Section 3 System Component Identification and Schematics ...
Страница 68: ...A B C D E F G H V Z Y X W 68 SJ30AJE SJ30ARJE 196274AF ...
Страница 128: ...128 SJ30AJE SJ30ARJE 196274AF Notes ...
Страница 189: ......
Страница 190: ...www skyjack com ...