TM
Page 28
December 2007
SJ 46A & SJ 46AJ
Visual and Daily Maintenance Inspections
Section 2 - Operations
2.8-6 Control Compartment
Ensure all compartment latches are
-
secure and in proper working order.
Base Control Console
•
Ensure all switches are returned to their
-
neutral positions.
Ensure there are no loose or missing
-
parts and there is no visible damage.
Hydraulic Tank
•
Ensure hydraulic filler cap is secure.
-
Ensure tank shows no visible damage
-
and no evidence of hydraulic leakage.
Hydraulic Oil
•
Be sure that the boom is in the stowed
-
position, and then visually inspect the
sight gauge located on the side of the
hydraulic oil tank.
The hydraulic oil level should be between
-
the minimum and maximum marks on the
sight glass. Add oil as needed. Refer to
Brake and Main Manifolds
•
Ensure all fittings and hoses are properly
-
tightened and there is no evidence of
hydraulic leakage.
Ensure there are no loose wires or
-
missing fasteners.
Emergency Power Unit
•
Ensure there are no loose or missing
-
parts and there is no visible damage.
Ensure there are no loose wires or
-
missing fasteners.
Ensure all fittings and hoses are properly
-
tightened and there is no evidence of
hydraulic leakage.
Fuel Tank
•
impORTANT
Before using your aerial platform ensure
there is enough fuel for expected use.
Ensure fuel filler cap is secure.
-
Ensure tank shows no visible damage
-
and no evidence of fuel leakage.
Hydraulic Tank
Brake Manifold
Main Manifold
Base Control
Console
Fuel Tank
Emergency Power
Unit