TM
Page 34
December 2007
SJ 46A & SJ 46AJ
Function Tests
Section 2 - Operation
Emergency
Stop
Base Control Console
Start/Function Enable/
Emergency Power Switch
Base/Off/Platform Key
Switch
2.9-1 Test Main Power Disconnect Switch
1.
In engine compartment, turn main power
disconnect switch to “
” off position.
Result:
Aerial platform functions should not
operate.
2.
In engine compartment, turn main power
disconnect switch to “ ” on position.
NOTE
Close all cowlings before proceeding to
next item.
2.9-2 Base Control Console
1.
On platform control console, pull out “
”
emergency stop button.
2.
For dual fuel engine, select fuel supply by moving
fuel switch to either “
” gasoline or “ ” liquid
propane gas position.
wARNiNG
Ensure that you maintain three points of
contact to mount/dismount platform.
Test Base Emergency Stop Light
•
1. On base control console, pull out
“
” emergency stop button.
Result:
Emergency stop light should
continuously illuminate.
2. Turn base/off/platform key switch to “
”
base position.
3. Start engine by selecting “
” start
position from start/function enable/
emergency power switch.
Test Base Emergency Stop
•
1. Push in “
” emergency stop button.
Result:
Engine should shut down and
aerial platform functions should not
operate.
2. Pull out “
” emergency stop button and
restart engine.