background image

15

SerVice anD inStallation Manual

Motion cut and other lMS inputs

and outputs

Go to menu 

5C

. Items 1 and 2 are the two LMS

outputs.  The  LMS indicates  if  the  outputs  is

supposed  to  be  in  ‘safe’  condition  or  ‘alarm’

condition. In ‘safe’ condition, a voltage will be

output on the motion cut wire.

Self-test

: if the self test indicates 

Pass

, it means

that  the  display  reads  back  the  expected

voltage. 

*important: 

The items #3 and #4 are usually inputs

connected to other equipment, switches or joystick.

The output function may indicate a fail and it is

normal  because  they  are  actually  inputs  in  the

default configuration. Access the menu 5E to verify

the status of those two inputs.
For test purposes, it is possible to set the signal of

an output manually, in this screen. To manually

change the output of a wire, select it and press the

enter

key. To have a voltage applied on a wire, its

status must be “Safe” and to have 0 volts on it, its

status must be “Alarm”. If the self-test indicates

“Pass”, it means that it reads the expected voltage

level. 
connector should have power on wires 10 & 11.

lMS lightbar diagnostic:

The LMS top five light should match the lights on

the  pipelayer  boom.  To  set  the  light  bars  in  a

specific way, look in the table which control wires

should be active.

Example: to light all 5 external lights, the LMS light

bar signals 1 & 3 should be active. Access menu

5C as shown above, turn those two signals to Safe

status, which means havnig votlage. For diagnostic

purposes, the LMS 

lMS input signals:

Alternatively  to  the  above,  access  menu 

5e)

digital input 

to see the status of the two digital

input signals:
No 1 Mute input

Off / On

No 2 Rigging mode input 

Off / On

System Sensors Diagnostic

1. Go to menu 

5a) S

ySteM

S

enSorS

D

iaGnoStic

.

2. Select the sensor and press 

enter

to see the

sensor data in menu 

5a1) S

enSor inForMation

.

3. Press 

exit

to return to menu 

5a)

and select an

other sensor or press 

exit

again to return to the

operation display.

radio network Diagnostic

1. Go  to  menu 

5B2)  l

aSt SenSorS receiVeD

.

Sensors are shown with their radio ID number

and the sensor type.

a. Use 

up

and 

Down

to scroll through the list.

b. Press 

exit

to return to menu 

5B).

2. Go to menu 

5B3) S

earch For SenSorS

.

a. Press 

enter

to launch a sensor search.

3. Go to menu 

5B4) B

it error rate teSt

. This test

should only be conducted by technical service

personnel.

4. Press 

exit

to return to the operation display.

Display Diagnostic

1. Go to menu 

5D) D

iSplay

D

iaGnoStic

1) t

iMe

: current time according to the LMS

internal clock.

2) D

ate

: current date according to the LMS

internal clock.

external light bar Control wires

Pin

Green #1

Light bar signal 1

9

Green #1&2

Light bar signal 2

10

Green #1,2&3

Light bar signal 3

11

All amber Light bar signals 1&2 9+10

All 5 lights

Light bar signals 1&3 10+11

table: Menu 5c - testing the outputs

1) A2B and Overload

Status: Safe

Self-Test: Pass

2) Free swing cut

Status: Safe

Self-Test: Pass

3) Mute input

Status: Safe

Self-Test: Pass*

4) Rig mode input

Status: Safe

Self-Test: Pass* 

5) Lightbar 1

Status: Safe

Self-Test: Pass

6) Lightbar 2

Status: Safe

Self-Test: Pass

7) Lightbar 3

Status: Safe

Self-Test: Pass

8) Optional  

Status: Safe

Self-Test: Pass

SkyAzul, Equipment Solutions

www.skyazul.com

301-371-6126

Содержание Trimble/LSI GM820

Страница 1: ...Trimble LSI GM820 Volvo With GS820 Display and Wireless Sensors Installation and Service Manual...

Страница 2: ......

Страница 3: ...y information which is protected by copyright and all rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of...

Страница 4: ......

Страница 5: ...tion lockout at 110 C Slope indicator show the pipelayer level d Slew indicator the arrow points toward the uphill direction The quadrant refers to the pipelayer upper body position The left side of t...

Страница 6: ...using Back next up and Down as described in password settings section and press enter alarm red lamp level All programmed and rated capacity limits and two block will generate an audible alarm when t...

Страница 7: ...e is available B0211_V1012 Sxxx zip It contains all the language packs mentioned above example if a system with the default language pack must be switched to Chinese 1 Download the language packs if i...

Страница 8: ...t be in contact with any metal object d The transmitter antenna should point to the left of the boom when viewed from the cab it should not point directly to or away from the display 2 Weld the mounti...

Страница 9: ...and clear the sensor chain and weight b Hoist slowly until the buzzer sounds Note the hoisting distance remaining this distance must be great enough to allow the operator and the lockout system if in...

Страница 10: ...t angle indication accordingly 2 4a angle calibration procedure 1 Mechanical Set up 1 Level the boom such that it is perfectly horizontal use a high quality bubble or digital angle sensor If the LMS d...

Страница 11: ...araMeter aDjuStMent 5 Use up and Down to select the angle sensor to be calibrated and press enter 6 Select 2 triM and press enter to modify 7 Use up and Down to modify the trim value example If angle...

Страница 12: ...Determine the sensor to be removed If more than one sensor of the same type has been added to the sensor list then determine the radio identification number ID of the sensor to be removed before proce...

Страница 13: ...munication with the sensor is possible and to start the wizard 4 Use up and Down to adjust the actual parts of line on the load sensor and then press enter to confirm 5 Note the units that will be use...

Страница 14: ...ed 4 Verify list and trim angle indication in the operation display They should change as shown in the picture For calibration use one of the two procedures below Minimum and maximum limits for list a...

Страница 15: ...o to menu 4 inStallation and select 4B SenSor caliBration 3 Enter the user password aza and press enter 4 Select 4B1 autoMatic caliBration WizarD 5 Use up and Down to select the trim or list sensor 6...

Страница 16: ...de the data logger analyzes the measured weight and records the peak value only One threshold per load cell must be adjusted When the weight drops by more than the peak threshold the peak weight is re...

Страница 17: ...nd will then have teh same ID It is the case for the load and anti two block A2B and for the trim list angles how to restore default factory settings It is possible to return the display to its factor...

Страница 18: ...Alternatively to the above access menu 5e digital input to see the status of the two digital input signals No 1 Mute input Off On No 2 Rigging mode input Off On System Sensors Diagnostic 1 Go to menu...

Страница 19: ...dition Verifythewireconnection RefertothePowerSupply and Lockout Connection sub section of this manual alert VeriFy White Wire ShorteD to GrounD description Voltage is not detected on the lockout wire...

Страница 20: ...on the key but its size is 0 kB Solution Did the transfer complete successfully Try again Problem The following message appears on screen during the transfer unaBle to create File replace uSB Solutio...

Страница 21: ...b Only dtl files generated by the LMS data logger can be displayed 4 3c Full report To export the full report to Excel click on the Full Report button in the tool bar table Full report column headings...

Страница 22: ...do not overtighten 5 5 MainTenanCe MainTenanCe 1 4 in 1 2 Hex key 5 32 in Flat bladed screwdriver 5 New high quality D cell battery 3 6 V lithium or alkaline Figure remove the sensor box from the moun...

Страница 23: ...e the white nylon hex bolt to the middle of the length of the new antenna 8 Coat the exposed metal foot of the new antenna with an electrical insulating compound by carefully inserting it in the mouth...

Страница 24: ...o corrosion is visible on the battery holder inside the load cell transmitter If some trace of corrosion is visible rub it off gently and put a small amount of dielectric grease on each battery holder...

Страница 25: ...length of a length sensor 3 Verify radio communication see Radio communication troubleshooting section Battery diagnostic Go to menu 5a SySteM SenSorS DiaGnoStic Select a sensor and press enter to ver...

Страница 26: ...ad length parallel 16F Sheave radius 16G Deduct 4D chart SettinGS 1 Rated capacity indicator 2 Pipelayer capacity chart interpolation 3 Out of charts default working load limit 4 Enable start section...

Страница 27: ...noStic 5a SySteM SenSorS 5B raDio netWork 5B1 RADIO NETWORk 5B2 LAST SENSORS RECEIVED 5B3 SEARCh FOR SENSORS 5B4 BIT ERROR RATE TEST 5c lockout 1 A2B AND OVERLOAD 2 FREE SWING CUT 3 MUTE INPUT 4 RIGGI...

Страница 28: ......

Страница 29: ......

Страница 30: ...2 SkyAz l Equipment Solutions www skyazul com 301 371 6126 SkyAz l Inc 16 Walnut Street Middletown MD 21769 Phone 301 371 6126 Fax 301 371 0029 info skyazul com www skyazul com...

Отзывы: