8.
•
Timer:
Timer for Bistabil output mode.
Valid entry:
1-65535sec
Factory default: all 0
•
Zone num.:
Only for „Zone follower” output types. It will follow the input zone selected.
Factory default: „Zone 1”
SMS remote controlling programming (Only with SPG 1000 ):
SPG 1000 and SPG 84 alltogether is could be used for SMS commanding and remote control.
If you would like to use these function you need to enable at „Configure” page „SMS Reply mode”
Warning:
Only standard English characters could be used.
SMS control:
If the phone nr of the sender of the SMS message to the SPG 84 is registered at USERs you may control SPG 84 with the
following commands :
•
SMS format:
OX=Y
Where “O” = output , “X” Number of the output 1...4, “Y” is the required status of the output 0= Out 1=In
Example: O1=1 Turning on Output nr 1
ARM
SPG 84 will be armed by this command module will reply with “ARMED !” answer
DISARM
SPG 84 will be disarmed by this command module will reply with a “DISARMED” answer
ALARM
Will trigger an immediate alarm module will reply with a “ ALARM ACTIVATED” answer
STAT
Requesting status of SPG 84,
Answer is :
[ Z1....Z8]
[BOX Tamper] [ACLOSS] [O1=x O2=x O3=x O4=x] [ARMED] [DISARMED] [STAY][ALARM]
Warning:
If SMS messages is stored in your phone and the phone is lost you will risk to let someone to remote control your system.