 SPG 84  Installation manual

2.

Hardware:

1.0.

 Main parts:

1  Fixing holes (4 of them)
2  Wired connectors
3  Control LEDs
   Outputs  O 1 –O 4
    LED 1 Green  –  1s flash Watchdog  ,    0,5  s  flas Watchdog communication with SPG 1000 is ready           
    LED 2 Yellow – Armed status       
    LED 3 Red    – Alarm status or communication through the expander socket
4  Expander socket  -10 pole at the solder side of the panel 
5 ibutton terminal 

Fixing holes:

There are 5 pcs of them on the panel at the side of the panel. Dimensions: 84 x 40 mm. 
All fixing holes are isolated, not connected to panel Ground. 

Wire terminals:

GND Ground
12V

+12 VDC in our output  terminal

O1-O4   Open collector outputs
In1-In4  Dual end of line resistor inputs for Z1....Z8  (In1 = Z1,Z2,  In2= Z3,Z4....)
GND Ground
iButton  Data  bus for iButton reader
Tamper input   Normally closed contact for enclosure or global tamper loop.
AC loss input   Its a Voltage input ! Requires independent 3 VDC. Its designed to work with Sky Laboratories battery backup 
power supply. Functioning as supervision of AC LED indicator. GND and voltage is independent from the panel's own circuit-

WARNING !  The 12 VDC socket is to be used for both supply the SPG84 panel and to power external devices. If SPG84 is 
not connected to SPG 1000 than power supply must be connected to these terminals. If SPG 84 is connected to SPG 1000, 
than SPG 1000 will supply SPG 84 and its external devices. In this case these terminals could be used to power external 
devices. Maximal current consumption for external devices are  200mA !
Connecting SPG 1000 and SPG 84 is allowed only at POWER OFF situation !

Expander board socket:

1

GND

2

12V 

7      TX   TTL 3,3 V serial port
8      RX   TTL 3,3 V serial port

Attention !

All connection in this socket is mostly direct to processor. Any misuse or inproper voltage will damage the SPG84. This sort of 
damage cause of inproper use of the soclet will void Warranty.

1.1.

Input wiring:

Wiring of the End of Line Resistors.:

Input: INx

Zone nr

Resistor value

1

Input 1

2,2K

Input 2

3,3K

2

Input 3

2,2K

Input 4

3,3K

3

Input 5

2,2K

Input 6

3,3K

4

Input 7

2,2K

Input 8

3,3K

Содержание SPG 84

Страница 1: ...ty alarm panel or techical transmission 4 Programmable remote controllable outputprogramozható General use The panel can be used independently with a downloadable programming software or it can be used as fully functional security panel with SPG 1000 multi path communication module SPG 84 designed to any 8 zone security installation where simplicity required arming and disarming is sufficient with...

Страница 2: ...aboratories battery backup power supply Functioning as supervision of AC LED indicator GND and voltage is independent from the panel s own circuit WARNING The 12 VDC socket is to be used for both supply the SPG84 panel and to power external devices If SPG84 is not connected to SPG 1000 than power supply must be connected to these terminals If SPG 84 is connected to SPG 1000 than SPG 1000 will supp...

Страница 3: ...urrent 50 mA Max current without outputs 70 mA Dimensions LxWxH 90x 46 20 x mm Terminal dimensions Ø2 5 mm Output load max 100mA 12VDC Input resistors 2 2K and 3 3K 10 Input status Only if SPG 1000 connected at SPG 1000 Status page Showing current status You may also change output status but changing outputs does not mean that the panel will change functions Example if an output is programmed to i...

Страница 4: ...ield will be added to the modules own zone numbers Example If you already have a 16 zone control panel than set this to 16 By doing so the 1st input of the zone will be numbered and reported as 17th Factory Default 0 Entry delay time Valid values 0 255 sec Factory Default 0 sec Exit delay time Valid values 0 255 sec Factory Default 0 sec Bell time Valid values 0 255 sec Factory Default 0 sec AC Lo...

Страница 5: ...hnical Similar operation of 24 hour zone but it will not trigger a Fire or Alarm message Its to be used if any sort of contact information is to be transmitted regardless if armed or disarmed status EG temperature sensor pump or other device activation e t c Follower A Follower zone will act as an Normal zone if it has been triggered by itself If a handover zone has triggered after a Delay zone th...

Страница 6: ...y ZT This is the enclosure or global tamper circuit pin No other zonetype can be programmed to this zone input ZA This is the panel AC loss detection tamper pin No other zonetype can be programmed to this zone input Dallas Ibutton arming disarming registration The SPG 84 can handle up to 8 different dallas ibuttons type 1990 Each iButton authority level could be set Dallas ID This is the hex code ...

Страница 7: ...entry time status of the SPG Communication Fail Will be activated if there is a communication failure between the SPG 1000 and the SPG 84 Zone Follower Will follow status of any zone selected Server control If SPG 84 receives a SMS command either from SMS or directly form SPG 1000 programming web AC Loss Will be activated if AC loss input is activated AC LOSS TIME OUT Will be acivated if AC LOSS t...

Страница 8: ...er of the SMS message to the SPG 84 is registered at USERs you may control SPG 84 with the following commands SMS format OX Y Where O output X Number of the output 1 4 Y is the required status of the output 0 Out 1 In Example O1 1 Turning on Output nr 1 ARM SPG 84 will be armed by this command module will reply with ARMED answer DISARM SPG 84 will be disarmed by this command module will reply with...

Страница 9: ...dicators Setting the outputs the following way iButton reader will indicate status of the SPG 84 expander module System Ready Green System Armed Red Exit Entry time Orange iButton wires Out 1 Connected to Out 3 Out 2 iButton Brown Out 3 iButton Green 12V iButton Yellow iB iButton White GND iButton Gray ...

Отзывы: