4.2.1 Master Unit Configuration
Step
Procedure
M1
Apply Power to the Master MMU II
M2
When the Screen displays the MMU Version and MSet
hold the * button (Upper Right) and press the KNOB in while making a
turn one click counter‐clockwise, then release both the knob and the *
button.
M3
The MMU II will now display the
BRIGHTNESS
CTL
page.
M4
Rotate the Knob (do not press in) clockwise until the
DIAL/In
‐
Call
Mech:
page appears.
M5
Ensure that the display is set at
DTMF/DTMF
M6
If not, TAB the knob and the selection will begin to flash.
M7
Rotate the knob until the
DTMF/DTMF
is displayed. Press the knob and
hold. The screen will display “
Value
Saved
SUCCESS”.
M8
Rotate the Knob (do not press in) clockwise until the
Volume
Tap:
appears.
M9
If required, TAP knob and select
Offhook
&
KeyIn
.
M10
Press the knob and hold. The screen will display
“Value
Saved
SUCCESS”
.
M11
Press the knob in and rotate clockwise one click. Release.
M12
The screen should display
Exit
Settings
Mode
.
M13
Press the knob in and release. The screen will now display
MMU
Ready
page.
M14
Master MMU II Configuration complete.
M15
Cycle Power to the Master MMU II.