Skov DA 74C Series Скачать руководство пользователя страница 22

22 

Technical User Guide 

 

DA 74C Winch Motor 

Maintenance Guide 

The DA 74C does not require any special maintenance, however we recommend that the system be serviced 
once a year. 

5.1 

Cleaning  

 

Clean the product with water and a brush without using: 

 

high-pressure cleaner  

 

solvents  

 

corrosive/caustic agents 

Figure 37: Cleaning 

5.1.1 

Annual Inspection 

1.

 

Open the cabinet cover to check the inside functions; check also that no fluid can penetrate into the 
cabinet as this may damage gears and other components. Pay attention to the shaft sealing and the 
sealing of cable lead-throughs.  
In case of sign of leakages, seal using silicone or replace the glands. 

2.

 

Activate the manual release and check that the swivel shutter moves unobstructedly in its entire 
working range. 

3.

 

For units with a contactor, check that the contactor is intact and can start and stop the fan when 
activating / deactivating. 

5.1.2 

Replacing the Motor 

The service life of the motor in a DA 74CV is limited, especially when it is used in connection with a MultiStep 
fan system in a large broiler house. 

The wearing part is the small round motor which should therefore be replaced every three years in order to 
ensure smooth operation. 

The service life of the DA 74CO is typically more than 10 years. 

 

Before removing the cover, switch off the power supply using the safety switch. 

 

1.

 

Disconnect the power supply and remove the cover. 

2.

 

Remove the motor plug 

(A)

3.

 

Loosen the shackle retaining the motor 

(B)

4.

 

Remove the motor. 

5.

 

Insert a new motor.  

6.

 

Tighten the shackle. 

7.

 

Mount the motor plug.  

8.

 

Position the plug correctly. 

9.

 

Mount the cover. 

10.

 

Connect the power supply. 

Figure 38: Replacing the motor 

(A) 

(B) 

Содержание DA 74C Series

Страница 1: ...2018 12 18 604148 DA 74C Winch Motor Technical User Guide For other language variants of this document we refer to http docs skov com 1077 or your local dealer...

Страница 2: ......

Страница 3: ...of this manual Note All rights reserved SKOV A S No part of this manual may be reproduced in any manner whatsoever without the express written permission from SKOV A S SKOV A S has made all reasonabl...

Страница 4: ...2 4 1 4 5 Connection in DA 74CO ON OFF 400 V 13 4 1 4 6 Circuit Diagram for DA 74CO ON OFF 400 V 13 4 1 4 7 Connection in DA 74CV Stepless 230 V 14 4 1 4 8 Circuit Diagram for DA 74CV Stepless 230 V 1...

Страница 5: ...on in the very harsh house environment The DA 74C supports the range of our computers capable of controlling MultiStep functions The DA 74C can open the swivel shutter manually if you press the manual...

Страница 6: ...A 74C The tools are not supplied by SKOV A S Item Description Multimeter Screwdriver set Side cutting pliers Long nose pliers Knife Water pump pliers Cordless drill Drill bits various sizes Adjustable...

Страница 7: ...ion The factory has prepared the winch motor for mounting on a closed swivel shutter Figure 2 Swivel shutter in closed position Press the DA 74C onto the swivel shutter shaft Mount the retaining disc...

Страница 8: ...s been mounted Press the push button Figure 6 B and check by turning the swivel shutter 3 1 5 Before Putting the System into Use the First Time To provide the winch motors with numbers attach the incl...

Страница 9: ...are not supplied by SKOV A S 4 1 1 Cable Routing All cables must be mounted in M25 glands according to Figure 8 protection class minimum IP65 Cables are to be secured in the usual way outside the cab...

Страница 10: ...ening degree Feedback signal 0 5 V O C turns ON Feedback signal 0 5 V relay turns ON ON OFF REVERSE Control voltage 24 V Close The feedback signal increases together with the opening degree 0 25 V clo...

Страница 11: ...or ON OFF Figure 11 Connection ON OFF 230 V 4 1 4 2 Circuit Diagram for DA 74CO ON OFF 230V Figure 12 Circuit diagram ON OFF 230 V 230 V L1 N 230 V L1 N BK BN N ON OFF H10 H11 H12 H13 H14 H15 PE H1 H2...

Страница 12: ...V external capacitor 4 1 4 4 Circuit Diagram for DA 74CO ON OFF 230 V with External Capacitor Figure 15 Circuit diagram ON OFF 230 V external capacitor 230 V L1 N 230 V L1 N BK BN N ON OFF L H10 H11 H...

Страница 13: ...400 V 4 1 4 6 Circuit Diagram for DA 74CO ON OFF 400 V Figure 18 Circuit diagram ON OFF 400 V BK BN 400 V L1 L2 L3 N L1 N A2 14 L3 L2 L1 A1 13 W V U L2 L3 400 V H10 H11 H12 H13 H14 H15 PE H1 H2 H3 H6...

Страница 14: ...e 20 Connection stepless 230 V 4 1 4 8 Circuit Diagram for DA 74CV Stepless 230 V Figure 21 Circuit diagram stepless 230 V 230 V L1 N 230 V L1 N N H10 H11 H12 H13 H14 H15 PE H1 H2 H3 H6 H7 H8 H9 H H10...

Страница 15: ...ess 230 V external capacitor 4 1 4 10 Circuit Diagram for DA 74CV Stepless with External Capacitor Figure 24 Circuit diagram stepless 230 V external capacitor 230 V L1 N 230 V L1 N N L H10 H11 H12 H13...

Страница 16: ...pless 400 V 4 1 4 12 Circuit Diagram for DA 74CV Stepless 400 V Figure 27 Circuit diagram stepless 400 V 400 V L1 L2 L3 N L1 N A2 14 L3 L2 L1 A1 13 W V U L2 L3 400 V H10 H11 H12 H13 H14 H15 PE H1 H2 H...

Страница 17: ...l 0 5 V relay turns ON Figure 28 Jumper for 0 10V Figure 29 Connection 0 10 V winch motor 4 1 4 14 Circuit Diagram for DA 74CVA 0 10 V Figure 30 Circuit diagram 0 10 V winch motor H10 H11 H12 H13 PE 0...

Страница 18: ...4 16 Circuit Diagram for DA 74CO ON OFF to DA 600 LPC 2 Figure 32 Circuit diagram DA 74CO and DA 600 LPC 2 Example of terminal no For correct connection see the setup menu Show Installation in Compute...

Страница 19: ...reaker Figure 33 Circuit diagram DA 74CO and DA 600 LPC 2 w thermal circuit breaker Example of terminal no For correct connection see the setup menu Show Installation in Computer Supply from emergency...

Страница 20: ...2 4 1 4 18 Circuit Diagram for DA 74CV stepless to DA 600 LPC 2 Figure 35 Circuit Diagram DA 74CV and DA 600 LPC 2 Supply from emergency opening or internal 24 V Q1 F6 Q2 Q5 When using ON OFF 278M an...

Страница 21: ...ircuit breaker Figure 36 Circuit Diagram DA 74CV and DA 600 LPC 2 w thermal circuit breaker Supply from emergency opening or internal 24 V Q1 F6 Q2 Q5 When using ON OFF 278M and 378M connect Q1 to C17...

Страница 22: ...uctedly in its entire working range 3 For units with a contactor check that the contactor is intact and can start and stop the fan when activating deactivating 5 1 2 Replacing the Motor The service li...

Страница 23: ...ding to local directions The recycling station will then send the products to an approved plant for recycling and reuse Before dismantling switch off the power supply for the DA 74C 1 Disconnect the p...

Страница 24: ...Check supply voltage Check fuses Check assembly according to connection and circuit diagram Mount the plug Press the CALIBRATE button the LED must be constantly on while the winch motor opens and clo...

Страница 25: ...edance 2 2 K O C open collector output max 20 mA 30V DC Cabinet insulation class IP 65 Table 4 Technical data Chimney DA 920 and smaller Bigger then DA 920 Winchmotor DA 75 DA 74 DA 75 DA 74 DOL 234F...

Страница 26: ...tives 2014 35 EU Low Voltage Directive LVD 2014 30 EU Electromagnetic Compatibility EMC 2006 42 EC Directive on Machinery 2011 65 EU RoHS Directive Standards EN 61000 6 2 2005 AC 2005 Generic standard...

Страница 27: ......

Страница 28: ...SKOV A S Hedelund 4 Glyng re DK 7870 Roslev Tel 45 72 17 55 55 Fax 45 72 17 59 59 www skov com E mail skov skov dk 2018 12 18 604148 8 2 3 EN Made in Denmark...

Отзывы: