![Skov DA 74C Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/skov/da-74c-series/da-74c-series_technical-user-manual_1289308011.webp)
Technical User Guide
11
DA 74C Winch Motor
4.1.4
Connection and Circuit Diagram for DA 74C
4.1.4.1
Connection in DA 74CO ON/OFF 230 V
ON/OFF
Control v24 V => Close.
Control voltage 0 V => Open.
Feedback signal > 0.5 V => O.C. turns ON.
Feedback signal > 1.8 V (15 degree opening) => relay turns ON.
Figure 10: Jumper for ON/OFF
Figure 11: Connection ON/OFF 230 V
4.1.4.2
Circuit Diagram for DA 74CO ON/OFF 230V
Figure 12: Circuit diagram ON/OFF 230 V
230 V
L1
N
230 V
L1
N
BK
BN
N
ON/OFF
H
1
0
H
1
1
H
1
2
H
1
3
H
1
4
H
1
5
P
E
H1
H2
H3
H6
H7
H8
H9
H
H10a
11a
+
C
A
L
IB
R
A
T
E
24V
ON/OFF
0V
24V
12a
Example of terminal no.
For correct connection,
see the setup menu
Show Installation in Computer
Supply from emergency
opening or internal 24 V
Q1
F6
Q2-Q5
When installing
DOL 278 ON/OFF
emergency opening
, connection of the
H6
is not necessary