68
Replacement Procedures
Service Manual
SKOPE VF Series
4. Connect the new fan motor wiring. The wiring diagrams below show EBM fan
motor wiring and UNADA fan motor wiring.
5. Reassemble the unit and perform electrical safety test
6. Test run the unit to confirm correct operation.The fan motors should run at
high speed (2200rpm) when the compressor is on, and low speed (1000rpm)
when the compressor is off.
EBM fan motor wiring (EBM
W1G200) (SKOPE part number
ELM9974)
UNADA fan motor wiring (UNADA-
UC FM103709R) (SKOPE part
number ELM11036)