21
SKOPE VF Series
SKOPE CAREL ir33 Controller
Service Manual
Program 485 BN1
Revision No.
1.4
Controller Code
BN1
BN2
BN3
Setting
Units
Access
Description of Parameter
Level
Min
Max
Password Parameter (PS) =
66
Probe Parameters
/2
4
-
C
1
15
/3
8
-
C
0
15
/6
0
-
C
0
1
/tI
1
-
C
1
7
/A2
2
-
C
0
5
/A3
5
-
C
0
5
/c1
0
°C
C
-20°C
20°C
/c2
0
°C
C
-20°C
20°C
/c3
0
°C
C
-20°C
20°C
Control Parameters
St
-21
°C
F
r1
r2
rd
3
°C
C
0.1°C
20°C
r1
-26
°C
C
-50°C
r2
r2
-16
°C
C
r1
200°C
r4
1
°C
C
-20°C
20°C
r4d
3
°C
C
-20°C
20°C
r5
1
-
C
0
1
rt
0
Hours
F
0
999
rH
0
°C
F
-
-
rL
0
°C
F
-
-
rHO
0
°C
F
-
-
rLO
0
°C
F
-
-
rdn
0
-
F
0
999
Compressor Parameters
c2
5
Mins
C
0
15
c3
5
Mins
C
0
15
c4
5
Mins
C
0
100
Defrost Parameters
d0
0
-
C
0
4
dI
8
Hours
C
0
250
dt1
4.5
°C
C
-50
200
dtn
6.5
°C
C
-50
200
dP1
45
Minutes
C
1
250
d6
2
-
C
0
2
dd
3
Minutes
C
0
15
d8
1
Hours
C
0
15
d8d
120
Seconds
C
0
250
d/1
0
°C
C
-
-
d10
20
Minutes
C
0
250
d11
-35
°C
C
-50°C
20°C
Alarm Parameters
A0
1
°C
C
0°C
20°C
AL
-30
°C
C
-50°C
200°C
AH
-11
°C
C
-50°C
200°C
AHO
50
°C
C
-50°C
200°C
Ad
120
Minutes
C
0
250
Hod
30
Minutes
C
0
250
A4
0
-
C
0
15
A5
1
-
C
0
15
A7
15
Minutes
C
0
250
A9
14
-
C
0
15
Ado
1
-
C
0
1
Ac
70
°C
C
0.0°C
200°C
AE
20
°C
C
0.1°C
20°C
A17
0
-
C
0
1
A18
4
-
C
0
7
Fan Parameters
F0
2
-
C
0
5
F1
-8
°C
C
-50°C
200°C
Fd
0
Minutes
C
0
15
Fon
2
Minutes
C
0
15
FoF
2
Minutes
C
0
15
Configuration Parameters
H0
1
-
C
0
207
H1
14
-
C
0
15
H2
1
-
C
1
6
H4
0
-
0
0
1
H5
15
-
0
0
15
H6
0
-
0
0
255
H10
3
-
C
0
15
H17
0
-
C
0
1
H18
1
-
C
0
1
H19
1
-
C
0
1
H20
0
-
C
0
1
H21
0
-
C
0
1
HACCP Parameters
HAn
0
-
C
0
15
HA.y_ _
0
Year
C
0
99
HA.Π_ _
0
Month
C
1
12
HA.d_ _
0
Day
C
1
31
HA.h_ _
0
Hour
C
0
23
HA.n_ _
0
Minute
C
0
59
HA.t_ _
0
Hours
C
0
99
HA1.y_ _
0
Year
C
0
99
HA1.Π_ _
0
Month
C
1
12
HA1.d_ _
0
Day
C
1
31
HA1.h_ _
0
Hour
C
0
23
HA1.n_ _
0
Minute
C
0
59
Calibration of probe 1
485
Electronic Controller Parameter Sheet
BN1
Available parameter sets for this program:
Standard Mode
CPS1008-485-BN1
ELZ3333AP-485
Last revised on
SKOPE ir33 Custom Controller
IRSKC0HF325 Rev 0.343
Controller Type
Application
VF Vertical Freezer (Integral)
SKOPE Part Number
Value to alter Set Point by when in Night mode
21 July 2015
Display
Range
Measurement stability
Probe display speed
Disable Decimal Point (0 = decimal point displayed)
Sensor shown on controller display
Probe 2 configuration (0=probe absent, 2=evap, 3=cond)
Calibration of probe 3
Differential
Probe 3 configuration (0=digital input, 2=evap, 3=cond)
Calibration of probe 2
Minimum compressor OFF time
Minimum compressor ON time
Comp ON time if Control Probe Fails (OFF Time = 15mins)
Max. Ambient temperature during period rt (Read only)
Min. Ambient temperature during period rt (Read only)
Number of door openings during period rt (Read only)
Temperature Set Point
Value to alter differential by when in Night mode
Enable monitoring (NOT related to HACCP)
Elapsed monitoring time (Read only)
Max temperature during period rt (Read only)
Min temperature during period rt (Read only)
Minimum Set Point allowed
Maximum Set Point allowed
End Defrost Temperature in night mode
Maximum defrost duration
Defrost type
Interval between defrosts (if not using real time clock)
End defrost temperature, (if d0 = 0 or 1)
Bypass alarms after defrost
Door Open Alarm Delay (0 = Door Alarm Disabled)
Display Evap 1 probe temp (Read only)
Display during defrost (0= dF (flash), 1 = temperature at start of defrost, 2 = dEF)
Dripping time after defrost
Alarm and fan differential
Low Temperature Alarm threshold (see A1 for absol. or rel. to Sp)
Compressor Running Time Defrost; Run Time
Compressor Running Time Defrost; Evaporator Temp. Threshold
Configuration of digital input 2
External Alarm On Delay (for A4,A5,A9 = 2). External Alarm Off Delay (for A4,A5,A9=1)
Configuration of digital input 3
High Temperature Alarm threshold (see A1 for absol. or rel. to Sp)
High Ambient alarm temp (see A1 for absol. or rel. to Sp)
Low and high temperature alarm delay
High ambient temperature alarm delay
Configuration of digital input 1
High ambient alarm mode (0 = Warning, 1 = Alarm)
Digital inputs Switching Config. N.O / N.C
Evap Fans Management Mode
Light output management mode with door switch
Condenser High Temperature Alarm
Condenser High Temperature Alarm Differential
Evap Fan On Time (when F0 or F0n = 4 or 5)
Evap Fan Off Time (when F0 or F0n = 4 or 5)
Evap Fans Start Temperature
Evap Fans Off Time After Dripping
Configuration relay AUX2 (R3)
Buttons to lock when keypad locked
Serial address
Configuration relay AUX1 (R2)
Keypad and IR Remote Control Functions (1 = All functions Enabled)
Disable buzzer (0=enabled, 1 = disabled)
Disable 'Quick View Inputs' Keypad Function (0=Enabled, 1=Disabled)
Configuration relay AUX3 (R4)
High Temperature HACCP Alarm - Number of Events Recorded
Enable Real Time Clock (RTC)
Enable RTC Alarm
Enable Day/Night Mode switching from Aux button (1 = Enabled)
Aux button assigned to Light or Aux output (0= Light output, 1 = Aux Output)
High Temperature HACCP Alarm - Year of 2nd most recent event
High Temperature HACCP Alarm - Month of 2nd most recent event
High Temperature HACCP Alarm - Day of 2nd most recent event
High Temperature HACCP Alarm - Hour of 2nd most recent event
High Temperature HACCP Alarm - Minute of 2nd most recent event
High Temperature HACCP Alarm - Month of most recent event
High Temperature HACCP Alarm - Day of most recent event
High Temperature HACCP Alarm - Hour of most recent event
High Temperature HACCP Alarm - Minute of most recent event
High Temperature HACCP Alarm - Duration of most recent event
High Temperature HACCP Alarm - Year of most recent event
Page 1 of 2