SKOPE VF Series
SKOPE CAREL ir33 Controller
Service Manual
Programming
Set-Point
The VF Freezer Range is manufactured with a pre-set control temperature
set-point. If this set-point does not match your required storage temperature
it is recommended that you change the set-point accordingly. The set-point
can be adjusted between a temperature range as detailed in the table below.
Temperature set-point
To view and adjust the temperature set-point
Parameter set
Operational mode Factory set-point Adjsutable
temperature range
485 BN1
Glass door lit
integral freezer &
solid door unlit
integral freezer
-21°C
-26°C to -16°C
485 BN2
Solid door lit
integral freezer
-21°C
-26°C to -16°C
485 BN3
Glass door ice
storage cabinet
-12°C
-18°C to -12°C
1. To view the set-point: press and hold
the
key for 2 seconds, until the
set-point value flashes
2. To adjust the set-point: press either the
and
keys to display the
required set-point value.
3. Press the
key again to memorise
the new set-point value. If this is not
done within 60 seconds, changes will
be lost and you will need to repeat the
above procedure.