![Skope OD1100N Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/skope/od1100n/od1100n_service-manual_1289215036.webp)
36
Replacement Procedures
Service Manual
SKOPE OD1100N
PIR Sensor
The electronic controller is fitted with a passive infrared (PIR) sensor to monitor activity inside
the fridge. The PIR sensor is located at the bottom of the cabinet opening.
10. Connect the cabinet to the power supply and use a mobile device to connect to the controller with
the SCS Connect Field app.
11. Navigate to the LOAD PARAMETER FILE menu.
12. Select the appropriate parameter file from LOCAL.
13. Confirm you have the correct file and select WRITE TO SCS.
14. After WRITE TO SCS is complete, select MENU > DISCONNECT to save the parameter set on
SCS Connect Field app.
15. Power cycle the controller and check that the parameter set has been applied.
16. Open the SCS Connect Field app and re-connect to the controller.
17. Use instruction sheet PRN80300 “Cabinet Setup using the SCS Field App” to configure the SCS
Info fields of the controller.
Procedure 25: To replace the controller (continued)
Procedure 26: To replace the PIR sensor
Before you start
Make sure you take note of the original PIR sensor cable’s path.
1. Disconnect the cabinet from the power supply (see page 18).
2. Remove the kick panel (see page 19).
3. Unplug the PIR sensor from the
cartridge electrics box (blue plug).
4. Remove the two screws, and lift the
return air grille out of the cabinet.