53
SKOPE BackBar X
Replacement Procedures
Service Manual
Control Probe
The control probe is located in the evaporator box, cable tied to a bracket
under the evaporator coil (see image below).
To replace the control probe
Evaporator
Probe
The evaporator probe is located within the evaporator coil.
To replace the evaporator probe
1. Remove the unit cover and isolate the chiller from the power supply (see
page 40).
2. Remove the refrigeration unit (page 46).
3. Unplug the probe from the unit electrics box.
4. Detach the probe from the bracket, and withdraw from the evaporator box.
5. Plug the new probe into the unit electrics box.
6. Following the same path as the original probe, run the new probe into the
evaporator box (use cable ties to hold the probe cable in place) and cable
tie to the probe bracket.
7. Use putty to seal up any gaps around the evaporator box entry point.
8. Reassemble the cabinet, reconnect to the power supply and check for
correct operation.
Control probe
1. Remove the unit cover and isolate the chiller from the power supply (see
page 40).
2. Remove the refrigeration unit (page 46).
3. Unplug the probe from the unit electrics box.
4. Remove the probe from the evaporator coil, and withdraw from the
evaporator box.
5. Plug the new probe into the unit electrics box.
Continued over page