51
SKOPE BackBar X
Replacement Procedures
Service Manual
Electronic Controller
Electronic
Controller
Location
The electronic controller is located within the electronic controller box
assembly.
To access the controller
Diagnostics
If the electronic controller has a suspected fault, care must be taken to
ensure accurate diagnosis. The controller has various programmable
parameters that effect operation such as time delay and defrost modes. Any
suspected failure must be double checked. Confirm all wiring and
terminations are correct. Check that the probe resistance is correct and
replace any faulty components. If operation appears erratic, check the
controller programming.
1. Remove the unit cover and isolate the chiller from the power supply (see
page 40).
2. Open the electronic controller box assembly by undoing the two fixing
screws at the rear of the assembly.