54
Replacement Procedures
Service Manual
SKOPE BackBar X
Condenser
Probe
The condenser probe is protected with insulating cork tape and attached to
the side of the condenser coil. It can be identified by its blue colour sleeve.
To replace the condenser probe
6. Following the same path
as the original probe, run
the new probe into the
evaporator box (use
cable ties to hold the
probe cable in place).
Feed the probe into the
8th fin on the evaporator
coil, and push 200mm
into the coil. Crimp the
fins to secure the probe
in place.
7. Use putty to seal up any gaps around the evaporator box entry point.
8. Reassemble the cabinet, reconnect to the power supply and check for
correct operation.
1. Remove the unit cover and isolate the chiller from the power supply (see
page 40).
2. Remove the refrigeration unit (page 46).
3. Unplug the probe from the unit electrics box.
4. Detach the probe from the side of the condenser coil.
5. Plug the new probe into the unit electrics box.
6. Following the same path as the original probe, fit the new probe with cable
ties and cork tape as necessary.
7. Reassemble the cabinet, reconnect to the power supply and check for
correct operation.
Condenser probe