background image

Installation Overview: 

 
The SC-12 Cab Master is an accessory to the base SC-12 system.  It is not required for proper 
operation of the control system.  An SC-12 Cab Master provides a convenient striping overview 
and can take control of either carriage, which allows it to be used as a spare SC-12 Master. 

Recommended location: 

The SC-12 Cab Master is usually located in the front cab, between the driver and passenger.  It 
can be used for single-operator operations or with a driver and passenger. 

Designation: 

Normal SC-12 Masters are designated Left or Right.  The SC-12 Cab Master has neither 
designation at shipping, but can override either side using the Quick Setup menu. 
 

Mounting:

 

The optimal viewing angle for the SC-12 Cab Master display is straight-on or from the bottom 
up.  Skip-Line recommends the SC-12 Cab Master be mounted in a manner that can be “tilted” 
so the top of the unit is further away from the operator than the bottom of the unit. 
 
The SC-12 Cab Master has nutserts on either side of the unit (to the left and to the right of the 
front panel).  These nutserts should be utilized so the SC-12 Cab Master is tiltable, using a 
U-shaped bracket. 
 
The nutserts accept a Skip-Line supplied #14-32 Hex Bolt. ¾” length (12mm x 1.75mm x 20mm) 

 

 
Please mount in a location free from exposure to: 

● Water  
● Pressure Washing 
● Excessive mechanical vibration 
● Temperature extremes 
● Intermittent, poorly regulated, highly inductive, or noisy power sources 

 

Communications Cabling 

 
The SC-12 Cab Master gets power and communications from one of the BUS-012 hubs (usually 
the front hub, although it does not matter) via a CAT5 cable. Connect the SC-12 Cab Master to 