Replace damaged cords immediately.
Use of damaged cords can shock, burn
or electrocute.
Always use proper extension cord. If an
extension cord is necessary, a cord
with adequate size conductors should be used to
prevent excessive voltage drop, loss of power or over-
heating. The table shows the correct size to use, de-
pending on cord length and nameplate amperage
rating of tool. If in doubt, use the next heavier gauge.
Always use U.L. and CSA listed extension cords.
NOTE:
The smaller the gauge number, the heavier the cord.
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Extension Cords
“SAVE THESE INSTRUCTIONS!”
Grounded Tools
Grounded tools must be plugged into an outlet properly
installed and grounded in accordance with all codes
and ordinances. Never remove the grounding prong or
modify the plug in any way. Do not use any adaptor
plugs. Check with a qualified electrician if you are in
doubt as to whether the outlet is properly grounded.
If the tools should electrically malfunction or break down,
grounding provides a low resistance path to carry electricity
away from the user. Improper grounding can shock, burn or
electrocute. Grounded tools are equipped with three
conductor cord and three prong type plugs. Before plugging
in the tool be certain the outlet voltage supplied is within the
voltage marked on the nameplate. Do not use “AC only”
rated tools with a DC power supply.
4.
WARNING
!
WARNING
!
X-Bench Accessory Control Box
Accessory Control Box
Only use the accessory control box for power tools designed
for use with accessory insert plates and suggested power
tools in this manual.
It is intended to be the mains switch for benchtop
applications if your Skil power tool is used in the insert plate.
It is also intended as a convenience outlet for use with your
Skil Circular Saw and Miter Saw.
Accessory Switch
The accessory control box has an accessory On/Off switch
with lock off key. Be aware of your position while using the X-
Bench for fast emergency shut off power. Remove lock off
key to disable switch when not in use.
Tool’s
Ampere
Rating
Cord Size in A.W.G.
Wire Sizes in mm
2
3-6
6-8
8-10
10-12
12-16
25
50
100 150
15
30
60
120
18
16
16
14
.75
.75
1.5
2.5
18
16
14
12
.75
1.0
2.5
4.0
18
16
14
12
.75
1.0
2.5
4.0
16
16
14
12
1.0
2.5
4.0
—
14
12
—
—
—
—
—
—
Cord Length in Feet
Cord Length in Meters
FOR CONTINUATION OF ENGLISH SEE PAGE 11