![SKF CAHB-20 Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/skf/cahb-20-series/cahb-20-series_installation-operation-and-maintenance-manual_1286969020.webp)
4.5 Connection
Fig 10
CAHB-2… connections
1
Wires to connect actuator to power
supply or to an external control.
4.6 Options
If not specified otherwise, the options listed below are available for
the entire series of CAHB-2… linear actuators.
4.6.1 Limit switch
The limit switch makes it possible to control the stroke of the linear
unit by internal setting. Contact the SKF to adjust the setting of limit
switch.
Remark: Limit switch is not available for CAHB-20
4.4 Construction group
description
Motor
The motor is a brushed DC motor, 12 or 24 V DC. The motor’s shaft is
connected to a helical gear. The lift speed depends on the load. The
motor unit is surrounded by metal housing and equipped by a EMC
filter. The metal housing cannot be opened.
Gear unit
The helical gear is directly powered by the motor shaft. Gear unit is
connected to the over load clutch that moves the drive screw system.
Linear unit
The linear unit is surrounded and protected by the guiding tube. The
linear unit of the CAHB-21E or CAHB-22E is equipped by brake. The
push tube of the actuator is connected to the nut of the drive screw
unit and aligned by the guiding tube.
1
20