![SKF CAHB-20 Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/skf/cahb-20-series/cahb-20-series_installation-operation-and-maintenance-manual_1286969012.webp)
The following safety features may have been
installed:
A thermal switch is integrated into the motor inside to prevent
damage from overheating. If overheating occurs when the actuator
is operating (over specification), the switch would be activated, the
power would be cut-off; after the temperature falls below the
threshold, the switch will restore..
CAUTION
To prevent damage from overheating, do not try to operate
actuator until its temperature has fallen below the threshold for
the switch to operate.
A driving screw nut converts the rotation of the gear unit into linear
motion. If an overload occurs when the actuator is operating, a ball
detent clutch will operate, thus stopping linear motion.
CAUTION
Continued operation of the clutch can result in overheating and
damage to the linear actuator. If clutch activates, switch off
power immediately.
Thermal switch
Overload protection
12