![SKF CAHB-20 Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/skf/cahb-20-series/cahb-20-series_installation-operation-and-maintenance-manual_1286969015.webp)
Fig 1
The product label provides the following
information
1
Power voltage
2
Rated Load
3
Rated current
4
Speed
5
IP level
6
Duty cycle
7
Identification of actuator (type key)
8
Part number
9
Customer part number
10
Serial number
11
CE mark
12
Manufacturer or the country of origin
3.2 Operating voltages and
limits
The operating voltages and the limits for standard version, including
when PWM is used for speed ramp up refer to:
12 V DC version: supply voltage
• For actuator: 12VDC ± 20%
• For Encoder: 4-20VDC
• For Potentiometer: Voltage limited by power 2 W
24 V DC version: supply voltage
• No limit switch option: 24 V DC ±10%
• Encoder option: 4–20 V DC
• Potentiometer option: Voltage limited by power 2 W
3.3 Product label
1
2
3
4
5
6
7
8
12
9
10
11