4.3 Special features
Mechanical overload protection
The actuator contains a mechanical overload protection unit (clutch).
This overload protection unit will activate if the linear unit of the
actuator overloads. This activation will avoid to push or pull over the
maximum force defined on the datasheet and will protect the motor
and gear unit from being damaged.
CAUTION
Continued operation of the clutch can result in overheating and
damage to the linear actuator. If clutch activates, switch off
power immediately.
CAUTION
To prevent damage from overheating when the actuator stop
with a high motor temperature, do not restart the actuator but
wait until the temperature decreases.
Gore automotive vent
The vent allows the equalization of the pressure inside the actuator
when it is operated, that will insure an optimum usage of the sealing
system
Thermal protection
The thermal switch built-in the motor will switch off the power of the
motor in case of over heat of the motor. It will automatically reset
when the temperature decreases.
Overload or more frequent operating the actuator over the max
duty cycles defined on the data sheet would lead to motor
overheating.