C AUTION
Do not operate pump in a way not in
accordance with instructions.
Do not operate with pump installed
incorrectly.
Failure to comply may result in
personal injury or damage to system
components.
Description
Electric Centro–Matic pump PS is
designed for automatic lubrication of
commercial vehicles, industrial, construction
and agricultural machines and wind
power plants.
PS pump is designed for single line (S)
parallel Centro–Matic type lubrication
systems. Pumps integrated design
includes all necessary components to
support Centro–Matic lubrication systems:
• Controller to program and monitor
lubrication cycle
• Choice of internal pressure switch or
internal pressure transducer
• Internal vent valve
• Three connected pumping elements
• External pressure relief valve
• Reservoir low–level control
• End of lubrication line pressure switch
or pressure transducer choice
• Contacts for remote monitoring
• V
or / V AC power supply
Pump can supply adequate lubricant to
bearings using SL–V, SL–V XL, SL–, SL–
and SL– injectors. Number of injectors
should be based on output of pump
being . in
/minute.
Pump for / V AC power supply can
be installed in any stationary industrial type
of applications requiring lubrication for same
number of medium size bearings.
NOTE
Installations using SL– and SL–
Lincoln injectors can lubricate more
than bearings.
Typical Centro–Matic system
schematic is shown on
page
.
Appropriate use
• PS pump is designed for intermittent
operation and is not suitable for continu-
ous operation.
• Pump is capable of supplying lubricants
up to NLGI . Refer to
Lincoln list of
lubricants
,
page
for list of recom-
mended greases.
• Any other use not in accordance with
instructions will result in loss of claims for
warranty and liability.