F2
30
31
F1
Diagram
Jumper settings for PS pump PCB
F – Fault relay for low level
F – Fault relay for pressure
– Relay contact switches to V
– Relay contact switches to ground
Default setting: Both relays switch to
ground (
) as shown
S – Industrial (AC)
M – Mobile (
)
With jumper – mobile (
)
Without jumper – industrial (AC)
TC – Time control
CC – Count control
Without jumper – time control
With jumper – count control
Shown with jumper
– Internal PS or PT
– Internal and external PS or PT
Without jumper – only internal PS or PT
With jumper – both internal and external
NO – Normally open low level switch
Used with reservoir without a follower
NC – Normally closed low level switch
Used with reservoir with follower
Without jumper – normally open low level SW
With jumper – normally closed low level SW
Without jumper – changing programming
parameters via keypad is possible
With jumper – changing programming
parameters via keypad is prohibited
Shown with jumper
Keypad