Configure LAN via
TCP

Configure Rhone2 LAN from PC via TCP

Connect Rhone2 directly to PC with patch cable.
Via Network configuration in PC, set gateway address in PC to 192.168.1.1.
Start TCP-terminal in the PC. Set connection parameters: ip 192.168.1.222, port 60000 and transfer method RAW.

When command window opens, use the following commands to change LAN configuration:
lanconf; Read current LAN settings.
lanip:; Set new ip. Example: lanip:192.168.7.44;
langw:; Set new gateway. Example: langw:192.168.7.1;
lanmask:; Set new ip. Example: lanmask:255.255.255.0;
lanactivate; Activate the changes.

Finally, reset Rhone2 by turning power to the product off/on.

LAN factory
settings

Product is delivered with the following settings:
Gateway IP 192.168.1.1
IP address 192.168.1.222
Network MASK 255.255.255.0
TCP port 60000
DHCP client deactivated.
MAC address can be found on the product label.

WiFi control

skdRhone2 app includes extension for communication via WiFi.
Connection via WiFi is established automatically at activation of the app, if Android device is connected to LAN via WiFi,
product is connected to LAN and communication between Android and Rhone2 is permitted over local LAN.
If Android device is connected to Rhone2 via USB cable, communication over USB has the priority.

Automatic fuse

The product includes in addition to physical 16A fuse also software controlled fuse.

Automatic fuse is by default enabled. Default current limit 16Ampere. Default latency 3sec.
AutoFuse settings can be changed via Web, TCP or from app.

If current through AC-switch exceeds preset threshold, AutoFuse will turn off AC-switch and get into disabled state.
If disabled, enable AutoFuse function to supervise current level.

NOTE: AutoFuse does not block the AC-switch function. It only turns off AC-switch in case current level exceeds the preset
threshold.

NOTE: SKD System AB assumes no responsibility or liability for consequences of using AutoFuse function. AutoFuse
function is software controlled.

Firmware upgrade

Unless distributed via e-mail, request latest version of firmware by sending e-mail to [email protected].

Firmware is upgraded via USB interface.

a) Copy firmware file image.hex to USB memory.
b) Turn off power to the product and insert USB-memory into Rhone2 USB interface.
c) Hold SW2 and turn on power. SW2 will start blinking fast after a couple of seconds. Upgrade is complete when blinking
stops.
d) If several Rhone2 nodes are installed in the same network, reassign the last three digits of MAC address to correspond
the MAC address on product label.
MAC address is reassigned via web under Upgrade, via app under About or by command lanmac:[last three digits in
MAC]; 
over TCP.

Restore factory
defaults

Alternative 1: Hold SW2 for 15sec, until LED2 stops blinking.
Alternative 2: From skdRhone2 Settings page select "Restore" icon.
Alternative 3: From product web page, Config page, select icon "Restore".
Alternative 4: Via TCP send command restore;

User Operation

Содержание Rhone2

Страница 1: ...control HTTP TCP USB control Android Wieland mini male connector connection to mains Wieland mini female connectors connection of electric equipment WiFi control from Android device via LAN Software controlled fuse in addition to physical fuse Dimensions L220 W100 H30mm Applications Power control on workplace Switching of power to power distribution lists and electrical equipment on workplace One ...

Страница 2: ...loor or after other types of mechanical distress Installation Mounting Mount Rhone2 into cabinet backside of desk underneath desk wall or other appropriate place Use velcro closing alternatively metal fixtures Velcro closing is included in delivery Connect power cables Connect product to the mains with cable that has Wieland mini GST15i3 female connector on the product end Connect product to equip...

Страница 3: ...be accessed directly from PC application from app or via scripted interfaceThere are also many examples of script interface There are many simple examples of how to communicate over serial interface using scripting language Python Indirect WiFi access from laptop PC or Android For access from Android use app skdRhone2 which can be downloaded from Google play Configure LAN from app Configure Rhone2...

Страница 4: ...ware controlled fuse Automatic fuse is by default enabled Default current limit 16Ampere Default latency 3sec AutoFuse settings can be changed via Web TCP or from app If current through AC switch exceeds preset threshold AutoFuse will turn off AC switch and get into disabled state If disabled enable AutoFuse function to supervise current level NOTE AutoFuse does not block the AC switch function It...

Страница 5: ... will connect automatically via WiFi Use of sensors Activate sensor and set sensor timers via web app or by command via LAN If activated when sensor detects presence it turns on AC switch AC switch is turned off automatically after preset timer period of no presence NOTE At activation of sensor control manual control is deactivated NOTE When power to the unit is turned on sensor will calibrate its...

Страница 6: ...TCP_PORT 60000 BUFFER_SIZE 5000 TCP_IP 192 168 1 222 s socket socket socket AF_INET socket SOCK_STREAM s connect TCP_IP TCP_PORT s send acsw 1 1 s close Example of command session Serial Interface Commands Common nodename Read node name nodename name Set node name Up to 12 alphanumerics Example nodename First Set node name to First who Read node id and name help Help lists commands and command gro...

Страница 7: ... reset the node to activate the change Example landhcp 1 Activate DHCP client AC switch h acsw Help AC switch commands acsw Read AC outlet states acsw id state Set AC outlet outport id 1 to off 0 or on 1 Example acsw 1 1 Turn on AC1 acsw 1 0 E meter h emeter Help E meter commands emeter Read E meter status and measurement results emeter id activate Start Stop KWH meter Example emeter 1 1 Start KWH...

Страница 8: ...ontrols AC1 If Orange AC1 is on activated by Sensor1 LED2 If off AC2 is disconnected If Green AC2 is turned on activated by SW2 command or via Android If Red Sensor2 is activated and controls AC2 If Orange AC2 is on activated by Sensor2 Fast blinking Green When holding for SW2 for 15 seconds to initiate restoring factory defaults Indirect Connection Over WiFi Connection between skdRhone2 app in An...

Страница 9: ...s 4sec Handling The fuse is a resettable fuse PTC Fuse increases its internal resistance at overcurrent on internal DC source The fuse resumes normal operation after fault is removed unless device was exposed to conditions outside of its normal operating area AC switch Function Switching of AC ports Connectors Wieland mini connectors 3pins GST15i3 white Male connector for connection to mains Femal...

Страница 10: ...le Function AC connector for connection of user equipment Type Wieland Gesis mini GST15i3 female Characteristics Rated 16A color white Indirect WiFi control Function Communication via WiFi from Android device indirectly via LAN Characteristics Communication between the Android app and the product over WiFi starts automatically when app is activated AutoFuse Function Software controlled fuse Comple...

Страница 11: ...vate Sensors Command acsw does not switch This is normal situation when Sensor1 and or Sensor2 are activated If Sensor1 and of Sensor2 are activated command acsw is deactivated To enable command acsw deactivate Sensor function by command psensor Example psensor 1 0 deactivates Sensor1 psensor 2 0 deactivates Sensor2 Sensor not working Check that sensor is activated Sensor is activated via Android ...

Страница 12: ...aults Default IP 192 168 1 222 If IP was set via DHCP client check DHCP server for ip address MAC address of the node can be found on the product label Alternatively check IP via app LAN control will not work if two nodes in the LAN have the same IP address If firmware was upgraded verify that the last three digits in MAC address of the product have been reasigned to correspond to the last three M...

Отзывы: