Configure LAN via
TCP
Configure Rhone2 LAN from PC via TCP
Connect Rhone2 directly to PC with patch cable.
Via Network configuration in PC, set gateway address in PC to 192.168.1.1.
Start TCP-terminal in the PC. Set connection parameters: ip 192.168.1.222, port 60000 and transfer method RAW.
When command window opens, use the following commands to change LAN configuration:
lanconf; Read current LAN settings.
lanip:; Set new ip. Example: lanip:192.168.7.44;
langw:; Set new gateway. Example: langw:192.168.7.1;
lanmask:; Set new ip. Example: lanmask:255.255.255.0;
lanactivate; Activate the changes.
Finally, reset Rhone2 by turning power to the product off/on.
LAN factory
settings
Product is delivered with the following settings:
Gateway IP 192.168.1.1
IP address 192.168.1.222
Network MASK 255.255.255.0
TCP port 60000
DHCP client deactivated.
MAC address can be found on the product label.
WiFi control
skdRhone2 app includes extension for communication via WiFi.
Connection via WiFi is established automatically at activation of the app, if Android device is connected to LAN via WiFi,
product is connected to LAN and communication between Android and Rhone2 is permitted over local LAN.
If Android device is connected to Rhone2 via USB cable, communication over USB has the priority.
Automatic fuse
The product includes in addition to physical 16A fuse also software controlled fuse.
Automatic fuse is by default enabled. Default current limit 16Ampere. Default latency 3sec.
AutoFuse settings can be changed via Web, TCP or from app.
If current through AC-switch exceeds preset threshold, AutoFuse will turn off AC-switch and get into disabled state.
If disabled, enable AutoFuse function to supervise current level.
NOTE: AutoFuse does not block the AC-switch function. It only turns off AC-switch in case current level exceeds the preset
threshold.
NOTE: SKD System AB assumes no responsibility or liability for consequences of using AutoFuse function. AutoFuse
function is software controlled.
Firmware upgrade
Unless distributed via e-mail, request latest version of firmware by sending e-mail to [email protected].
Firmware is upgraded via USB interface.
a) Copy firmware file image.hex to USB memory.
b) Turn off power to the product and insert USB-memory into Rhone2 USB interface.
c) Hold SW2 and turn on power. SW2 will start blinking fast after a couple of seconds. Upgrade is complete when blinking
stops.
d) If several Rhone2 nodes are installed in the same network, reassign the last three digits of MAC address to correspond
the MAC address on product label.
MAC address is reassigned via web under Upgrade, via app under About or by command lanmac:[last three digits in
MAC]; over TCP.
Restore factory
defaults
Alternative 1: Hold SW2 for 15sec, until LED2 stops blinking.
Alternative 2: From skdRhone2 Settings page select "Restore" icon.
Alternative 3: From product web page, Config page, select icon "Restore".
Alternative 4: Via TCP send command restore;