SKC Quick Take 15 Скачать руководство пользователя страница 1

Operating Instructions

Catalog No. 228-9515

SKC Inc.

863 Valley View Road

Eighty Four, PA 15330 USA

Form #40076—Rev 0710

Содержание Quick Take 15

Страница 1: ...Operating Instructions Catalog No 228 9515 SKC Inc 863 Valley View Road Eighty Four PA 15330 USA Form 40076 Rev 0710 ...

Страница 2: ......

Страница 3: ...rranty 21 Ordering Information 22 Notice This operating instruction may not address all safety concerns if any associated with this product and its use The user is responsible for determining and following the appropriate safety and health practices and regulatory limitations if any before using the product The information contained in this document should not be construed as legal advice opinion ...

Страница 4: ......

Страница 5: ...ays press to start sampling To Run or Hold Press To repeat a sample run From Done reset rSEt or sampling error SErr press to return to run time preset Press to sample To change or calibrate flow Note Flow rate does not appear on LED Press or and scroll to a run time preset Press and hold CAL for 2 seconds Does not require a security code Press or to change flow rate until desired flow appears on c...

Страница 6: ......

Страница 7: ... features a programmable timer that provides up to eight programmable run time presets of 1 to 999 minutes continuous run with manual shut off or intermittent sampling A rechargeable lithium ion battery pack provides run times up to four hours Charging jack on side of case not shown High contrast LED display for readout of presets run time and battery status Calibration mode button Up arrow increa...

Страница 8: ...32 113 F 0 45 C Protect sample pump from weather when in use outdoors Run time features User selectable features user adjustable presets see Advanced Setup Preset timed runs 1 2 5 10 or 15 min Manually set continuous run with manual shut off 1 to 999 min repeats 1 to 999 min runs indefinitely until user stops pump or power supply is depleted Intermittent sampling See Advanced Setup Flow fault feat...

Страница 9: ...s Rechargeable lithium ion batteries in SKC pumps are subject to the A 45 exemption to the IATA regulations and are not regulated for air shipments This information must be written on the shipping document when shipping by air For ground shipments US DOT regulations specify a limit of 24 or fewer battery cells in one shipping box If you exceed 12 QuickTake 15 pumps with battery packs in one shippi...

Страница 10: ...pacity remaining Battery charge is low charge battery approximately 1 to 25 battery capacity remaining Low Battery Fault Pump will stop running beep and go to sleep in 10 seconds To operate from AC power The QuickTake 15 may be run using AC power with the AC charger adapter with battery Insert the charger plug into the jack on the pump and the charger into a standard wall outlet Operate the pump T...

Страница 11: ...activate the LED by pressing and holding To interrupt run terminate a sample or reset pump From Hold press Sample reset rSEt will display Press to reset pump or to ignore reset and return to Hold To set flow or calibrate See Calibration and Setting Flow for details 1 Connect a flowmeter to the pump inlet 2 Scroll to any run time preset Press and hold CAL for 2 seconds to enter calibration mode pum...

Страница 12: ... established Calibration Note Flow rate can be calibrated by pushing the bowl end of a second cassette adapter onto a spore trap cassette inlet seal removed attaching flexible tubing to the tube end of the second adapter and attaching the other end of the flexible tubing to the outlet of a calibrator Sampling with Sampling Wand Accessory Cat No 228 9521 Insert the tube end of a cassette adapter in...

Страница 13: ... flashing CAL will appear on the LED 3 Press or to increase or decrease the flow until the desired flow rate is displayed on the calibrator 4 Press A flashing Stor will appear on the LED To save new setting Press The pump will stop running To ignore new setting Press The pump will stop running Note A security code is not needed to change flow rate It is only required when changing factory settings...

Страница 14: ...wn to zero run time remaining below one minute is displayed in seconds with a colon The pump will stop and beep four times The display will flash Done 3 Press to return to the run time preset display If the user wishes to repeat the sample press User Options During Timed Run Sampling Viewing battery status Press Display will automatically return to run time remaining after five seconds or press ag...

Страница 15: ...ed The LED will display cumulative run time and Hold alternately To continue sample run Press To terminate sample and reset pump Press while in Hold Sample Reset rSEt will flash on the LED Press User Options During Continuous Run Sampling Viewing battery status Press Display will automatically return to cumulative run time after five seconds or press again Hold mode Press while the sample is runni...

Страница 16: ...lay will flash Done Press to return to presets If a repeat sample is desired press b Continuous Run mode The timer will count up to 999 minutes automatically reset to zero and count again to 999 minutes until user stops the pump Press to place the pump in Hold when the desired sampling time has elapsed Hold and cumulative run time will flash alternately Press while in Hold Sample reset rSEt will a...

Страница 17: ...ssive back pressure a flashing FLOF will appear on the LED If the fault is not corrected within five seconds the pump will beep four times and stop running Restoring Sampling from a Flow Fault Fault restart manufacturer default enabled Fault restart will attempt to restart the pump every 10 seconds up to five times Cumulative run time can be displayed by pressing Press again to return to the fault...

Страница 18: ...s desired press to move to delay time 2 When finished press Stor will flash on the display To save new setting Press Press to move to delay time setup To ignore new setting Press Display will move to the delay time If displayed values are not changed the flashing Stor will not appear and pressing will move the display to the next parameter to be set Setting Delay Time d 1 Press or to increase or d...

Страница 19: ...play will flash Done after the desired cycles are completed Press to display cumulative run time Press to return to Done Press to return the display to the run time preset If a repeat sample is desired press Intermittent sampling settings are retained when pump goes to sleep Digital display Sample run completed Digital display Set number of cycles User Options During Intermittent Sampling Viewing ...

Страница 20: ...preset is selected Choosing End will truncate the stored preset sequence see below For example if the user desires to store only two presets preset time 3 can be set to End shortening the number of presets to scroll through Times programmed for preset times Pt 4 through 8 will not display until the presets are changed to make them display or the factory defaults are reset see Resetting Pump to Man...

Страница 21: ...lt Digital display Pump default Digital display No do not reset to pump default Enabling Disabling Alarm and Fault Features 1 Press the security code to enter setup mode 2 Press CAL The pump serial number will display briefly 3 Press or to turn feature on or off see below Press to advance to next feature 4 Press to exit feature setup Press again to return to run time presets Feature ON OFF Button ...

Страница 22: ...e Inlet Filter This requires a Phillip s head screwdriver Lift off battery compartment door Remove 8 screws from back plate Battery pack is wired to control board inside pump Lift back plate carefully and set to the side of pump Remove 6 screws from housing plate Lift up housing plate Note position of two O rings 3 4 5 6 7 Orient pump with back facing upward Remove 6 screws from battery compartmen...

Страница 23: ... plate Check that the stack tubing and control board wiring inside the case are in place and will not be pinched The back plate should seat evenly without pressure Ensure battery pack is positioned horizontally and is seated in the foam on top of the back plate See photo in Step 3 for placement Replace 8 screws in the back plate Tighten screws alternately Replace the battery compartment door Repla...

Страница 24: ... Remove the six screws from the battery compartment cover 2 Lift out the battery pack and disconnect it 3 Connect the new battery pack and insert it into the battery compartment 4 Re attach the battery compartment cover with the six screws Screws Screws Battery pack Cautions and Warnings To reduce risk of injury fire or electric shock always follow basic safety precautions when using this product ...

Страница 25: ...s Leland Legacy Pump 2 pumps QuickTake 15 12 pumps QuickTake 30 3 pumps AirChek XR5000 6 standard Li Ion model pumps or 3 high power Li Ion model pumps 3 Ship to SKC freight prepaid to the following address SKC Inc National Service Center 863 Valley View Road Eighty Four PA 15330 SKC Inc will accept for repair any SKC product that is not contaminated with hazardous materials Products determined to...

Страница 26: ... of use loss of time loss of profits loss of income or other incidental damages Nor shall buyer be entitled to recover from SKC Inc any consequential damages resulting from defect of the instrument including but not limited to any recovery under section 402A of the Restatement Second of Torts 3 This warranty extends only to the original purchaser of the warranted instrument during the term of the ...

Страница 27: ...E marked model with 223 245 charger 100 240V 228 9515B QuickTake 15 Sample Pump Charger and Rotameter 115V 228 9515A QuickTake 15 Sample Pump Kit includes pump rotameter charger wand tripod stand and carry case 115V 228 9515K CE marked model with 223 245 charger 100 240V 228 9515KB Replacement Parts Stem Tubing Adapter pk 2 P31239 Cassette Adapter P33100 Replacement Inlet Filters O ring Set 5 filt...