Power specification
Power input to the modem is protected against reverse polarity and over-voltage.
The modem’s power consumption is as follows:
Table 7 – Power consumption
Model
Draw in mA (at 12 VDC)
Standby
Transmitting
Peaks
BT-5600v2
123
221
452
BT-5800v2
123
328
810
BT-6401
115
246
417
BT-6421
229
360
531
BT-660x
115
213
444
BT-6621
249
347
578
BT-6800
115
320
802
BT-680x
115
320
802
BT-6821
249
454
936
Wiring instructions are provided in the
Hardware Installation
section.
All modems are equipped with protection for reversed polarity and power surges over 33 volts. The modems are
equipped with an internal 3 Amp fuse. When using the 4 pin Molex connector / power accessory cable supplied by
BlueTree Wireless, an extra 2 Amp fuse is also included (5600v2, 5800v2).