7.4.6 Twine tension adjustment
Each twine must come out of the clamp (ref. 1, Fig. 7.17) when subjected to a force F1 = 2
–
3 kg (Fig.
7.17) and must run along its path outside the needle when subjected to a force F2 = 10
–
14 kg (Fig.
7.17). If necessary, adjust the pressure of the clamp 1 (Fig. 7.17) with the screw 2 (Fig. 7.17).
Fig. 7.17