With the needle arm in neutral, during the raising of the needle, the minimum distance between the
tip of the twine guide cam and the inner side of the needle must be 2
–
3 mm (ref G2, Fig. 7.16).
If the needle height adjustment made as indicated in section 7.4.4 does not allow the above distances
from the crescents to be complied with, the previous needle height adjustment will have to be
corrected.
Fig. 7.16