42
3.7
ELECTRICAL INSTALLATION
The rake can be powered by either of the two methods described below (Option A and option B).
Option A
– Lighting connector
The SAE J560 standard specifies a ground connection at pin (1) and continuous 12 V / 30 A power at pin
(7).
If the tractor is equipped with a seven-way receptacle that meets the standard, the rake lights and the control
box will work properly with only the lighting connector
attached to the tractor.
Pin number
Function
1
Ground
2
NOT USED
3
Left-hand hazard / turn signal (Amber)
4
Brake lights (Red)
5
Right-hand hazard / turn signal (Amber)
6
Tail lights (Red)
7
12 V Auxiliary power