Menu Selection 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Main Menu Items 

 

Schedules > Optional, used to view and set programmable schedules 

 

User Settings > set various user preferences  

 

Away Setpoints > show and set the heating and cooling setback setpoints 

 

Thermostat Info > displays thermostat setup info 

 

MiWi Network Info > shows network information 

 

Schedules

 

is an optional menu item. It will only show up in the menu list if “Schedules” 

is enabled in the Installer settings for the thermostat.  Provides for local schedule control.  

The Schedules Screen allows you to review and set the setback schedule for the 

thermostat.  The thermostat has a 4 x 7 schedule.  Four times a day can be selected for 

changes to the heating and cooling setpoints.  Each day of the week can have a different 

schedule.  Groups of days can be copied with the same schedule.  When the thermostat is 

set to “Run” mode, the schedule will be executed daily, with the setpoints being changed 

as per that days schedule stored in the thermostat.  “Hold” mode stops schedule operation 

and holds the current setpoints until changed manually or by network commands. 

 

The Schedules Screen gives you the option of setting a custom setback schedule or to 

load one of two preset schedules. 

Press Menu button to go 

to the main menu screen    

Use the 

UP/DOWN 

buttons to select 

the desired menu 

item 

Press SELECT to go to the 

menu item screen 

Press DONE to go back to 

the main thermostat screen 

4:30

 PM 

Menu Selection 

Select 

Schedules 

User Settings 

Away Setpoints 

Thermostat Info 

Done 

  

75 

MENU 

HEAT 

MODE 

HOLD 

64H 

82C 

AUTO 

FAN 

Sys Off 

  

Thermostat Name 

 

DCN: 140-02302-01 

Page 16 

 

User Settings 

Select 

Set Clock 

Filter Service 

Maint Service 

Screen Timeout     0 

Done 

  

Heat  and Cool 

Preset: Comfort 

Preset: Energy Miser 

Select Schedule 

Select 

Done 

  

 

Menu Options 

 

Heat and Cool:

  You can change the individual day/hour  

and setpoints for the Heating and Cooling schedule by selecting 

this menu item. 

 

Preset:  Comfort:

  This is a preset schedule with mild setbacks. 

Select this menu item to load the Comfort schedule into the  

thermostat.  Confirmation screen will be displayed for Yes/No entry. 

 

Preset: EnergyMiser:

 This is a preset schedule with deeper setbacks.   

Select this menu item to load the EnergyMiser schedule into the thermostat.  

Confirmation screen will be displayed for Yes/No entry. 

 

Day Schedule Screen 

When you select the Heat and Cool Schedule menu item,  

the “day” schedule programming screen opens and the  

schedule for current day will be displayed.  Use the scroll buttons 

 to highlight the data to be modified.  Once the data has been  

highlighted, use the +/- buttons to change the value of the data.  

 

To copy a days schedule to another day or group of days, move the cursor to “

C

” on the 

bottom right of the schedule screen.  When you highlight the “

c

”, the button below will 

become “Copy”.  Press this button to change to the Copy Schedule Screen.   

 

 

Copy Schedule Screen 

The Copy Schedule screen is a sub screen of the Schedule screen.  

The Copy Schedule screen allows you to copy a day’s schedule 

to another day or group of days. 

 

First select the day to be copied in the Schedule screen.   

Scroll to the “

c

” at the bottom of the Schedule screen to highlight it.   

The “Next” button will change to the “Copy” button.  

Press the “Copy” button to open the Copy Schedule screen. 

 

Scroll through the days and select the days you want to copy the schedule to by setting the 

N

” under each day to “

Y

” by using the Yes/No buttons. 

 

After selecting all the days desired, press the “COPY” button. 

 

Exit the Copy Schedule screen with the “DONE” button. 

 

 

 

User Settings Menu Items 

 

Set Clock > go to the clock setting screen 

 

Filter Service > go to the filter timer setup screen 

 

Maint Service > go to the maintenance timer setup screen 

 

Screen Timeout > sets the time in seconds to switch to the 

 minimized screen 

 

RH Setpoint > Setpoint for RH control 

 

F/C Settings > go to the F/C mode selection screen 

 

Sensor Calibration > go to the sensor calibration screen 

 

Backlight/Display > go to the backlight and display setup screen 

BACK 

COPY 

Copy Monday Schedule 

  

                          To 

  

 Tue  Wed  Thu  Fri  Sat  Sun 

   N      N      N     N     N     N 

Yes 

 

No 

 

DONE 

NEXT 

Monday Schedule 

  

           Time       Heat    Cool 

Wake  06:00 A     70      79 

Day     08:00 A     62      85 

Eve     04:00 P     70      78 

Sleep  10:00 P     62      82   C 

Содержание TM46

Страница 1: ...re to set the change over type in the Installer Settings menu to C O Type w Heat Otherwise leave it set to w Cool DCN 140 02302 01 Page 2 Standard HVAC System G Fan W1 Heat Stage 1 Y1 Compressor Stage 1 R 24VAC Return C 24VAC Common Thermostat Connection Y2 Compressor Stage 2 W2 Heat Stage 2 Optional 24R Connection for single transformer HVAC Systems RC and RH are jumpered together on thermostat b...

Страница 2: ...d Stage Cool Enable second stage cooling outputs If you have a single stage cooling system leave this set to N If you have a two stage cooling system set to Y to enable 24RC W1 24RH W2 O RS1 RS1 RSC 24C Cooling 24V Fan Cooling stage 1 Cooling stage 2 Remote Sensor 2 Remote Sensor 2 Sensor shield 24VAC Com 24V Heating Aux Heating Change Over Valve Remote Sensor 1 Remote Sensor 1 Sensor shield Remot...

Страница 3: ...N these settings affect HVAC system operation and should only be changed by qualified HVAC service technicians Installer Settings Menu Items Display Lock Options Y or N Default N Y Display LOCKED N Display UNLOCKED Allows you to lock or unlock the thermostat buttons When the buttons are locked you can still access the main menu but you will not be allowed to select any menu options The Installer S...

Страница 4: ... or accept setpoints higher that this maximum Options 40F to 109F 4C 43C Default 90F 32C Min Cool SP Sets the minimum cooling setpoint value Will not ramp or accept setpoints lower than this minimum Options 44F to 113F 6C 45C Default 60F 15C Min Run Time MRT Sets the minimum run time before a heating cooling cycle turns off Sets heating cooling cycle time Prevents rapid cycling Options 1 9 Minutes...

Страница 5: ... 2 Type 3 Type 3 RS2 Location Indoors or Outdoors In Out In Restore Defaults factory defaults Yes or No No Exit no USER SETTINGS Filter Service Submenu Service Interval Disabled 100 4000 hrs 300 Maint Service Submenu Maint Interval Disabled 100 4000 hrs 3000 Screen Timeout to minimized screen 0 20 120 sec 0 0 off will not timeout RH Setpoint 40 70 50 F C Settings F or C F Sensor Calibration Submen...

Страница 6: ...n Auto mode the mode of the last system call will be the setpoint screen displayed Setpoint Push Note that you cannot lower the cooling setpoint below the heating setpoint The thermostat will push the heating setpoint lower if you try to lower the cooling setpoint below the heating setpoint It maintains a 3 degree separation between the heating and cooling setpoint The same is true for raising the...

Страница 7: ...ors Optional Fan Mode Fan Cycler If the Fan Cycler feature is enabled in the Installer Setup the additional fan mode Cycle will be shown in the Fan Mode menu This mode cycles the fan on and off continuously for fresh air ventilation according to the settings in the Installer Setup System Status Indicators When the main thermostat screen is displayed the on screen labels indicate the following Syst...

Страница 8: ... menu item to load the Comfort schedule into the thermostat Confirmation screen will be displayed for Yes No entry Preset EnergyMiser This is a preset schedule with deeper setbacks Select this menu item to load the EnergyMiser schedule into the thermostat Confirmation screen will be displayed for Yes No entry Day Schedule Screen When you select the Heat and Cool Schedule menu item the day schedule...

Страница 9: ...een and the current number of degrees of offset being applied typically 0 If the sensor s actual temp is 75 with 0 degrees of offset and you want it to display 76 then press to add 1 deg and it will indicate 76 in the display with 1 deg offset You can refresh the info on this screen by pressing the right hand blank button When you close this screen it may take a few seconds for the temperature dis...

Страница 10: ...it does not respond immediately due to another call that has recently completed and the MOT delay timer is preventing the system from restarting The MOT delay time can be adjusted in the Installer Settings menu of the thermostat There is a minimum of 5 minutes delay to assure compressor protection Note The MOT status is shown in the thermostat System Status on screen labels DCN 140 02302 01 Page 2...

Страница 11: ...quipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Any chan...

Отзывы: