background image

DCN: 140-02302-01 

Page 13 

 

Setting the System Mode: Off, Heat, Cool, Auto 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System Modes 

 

OFF

: System is off.  No heating or cooling will come on.  If system was on, it will turn 

off immediately. 

 

HEATING:

  Only heating will occur. 

 

COOLING:

  Only cooling will occur. 

 

AUTO:

  Heating or cooling will come on according to the heating and cooling 

setpoints.  The system will automatically switch between heating and cooling modes 

as needed to maintain the setpoints.  

 

Special Heat Pump Mode: Emergency Heat 

 

EHEAT:

  An additional system mode, “EHEAT” for Emergency Heat will be displayed 

if the HVAC system type is set to Heat Pump.  If

 

there is a compressor failure with the 

Heat Pump system, setting the mode to EHEAT will allow the supplemental Aux heat 

to come on first whenever there is a call for heating.  It also disables the compressor 

output to prevent further damage to the HVAC system. 

Press the  

UP or  

DOWN buttons  

or 

 MODE button  

to select the 

desired system 

mode

 

System Mode change screen 

Press Mode button to 

change system mode 

Press “DONE” button to select the mode and exit back to the main 

thermostat screen or wait for the screen to automatically time out. 

Done 

  

MODE 

 

 

  

  

SYSTEM MODE 

OFF 

HEATING 

COOLING 

AUTO 

4:30 PM 

75 

MENU 

HEAT 

MODE 

HOLD 

64H 

82C 

AUTO 

FAN 

Sys Off 

  

Thermostat Name 

 

DCN: 140-02302-01 

Page 14 

 

Setting Fan Mode and System Status Indicators 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Optional Fan Mode 

Fan Cycler.

  If the Fan Cycler feature is enabled in the Installer Setup, the additional fan 

mode “

Cycle

” will be shown in the Fan Mode menu.  This mode cycles the fan on and off 

continuously for fresh air ventilation according to the settings in the Installer Setup. 

 

System Status Indicators 

 

When the main thermostat screen is displayed, the on-screen labels indicate the following.   

 

 

System Operation mode indicator

 

“SYS OFF” displayed >  System is OFF  

“SYS MOT”

1

 displayed >  System is OFF and Minimum Off Time (MOT) delay On is active   

“HEAT ON” displayed >  System is ON and heating  

“COOL ON” displayed >  System is ON and cooling  

“HEAT MRT”

2

 displayed > System is ON and heating.  Minimum Run Time (MRT) delay off 

is active.  

“COOL MRT” displayed > System is ON and cooling.  Minimum Run Time (MRT) delay off 

is active. 

 

Staging display   

“2

nd

 Stg” displayed > Stage 2 heating or cooling is ON 

“Aux Heat” displayed > Stage 3 heating is ON 

For Heat Pump systems only: “EHEAT” > emergency heat mode active 

 

Home/Away display 

Home

 mode is active  (current setpoints are being used)  

Away

 setback mode is active (setback setpoints are being used) 

 

System Alerts

 

Alert Text displayed > Specific alert text (Filter or Maintenance Timer) 

 

Notes 1 and 2:  See MOT and MRT descriptions on page 18

Press the Fan button to change the Fan mode 

 

 

AUTO FAN:  Fan automatically operated by the HVAC system. 

 

FAN ON:  Manual Fan mode.  Fan stays on until mode is changed back to Auto. 

System 

Status 

Indicators 

75 

MENU 

HEAT 

MODE 

HOLD 

64H 

82C 

AUTO 

FAN 

Sys Off 

  

2

nd

 Stg 

Filter 

4:30 PM 

Thermostat Name 

 

Содержание TM46

Страница 1: ...re to set the change over type in the Installer Settings menu to C O Type w Heat Otherwise leave it set to w Cool DCN 140 02302 01 Page 2 Standard HVAC System G Fan W1 Heat Stage 1 Y1 Compressor Stage 1 R 24VAC Return C 24VAC Common Thermostat Connection Y2 Compressor Stage 2 W2 Heat Stage 2 Optional 24R Connection for single transformer HVAC Systems RC and RH are jumpered together on thermostat b...

Страница 2: ...d Stage Cool Enable second stage cooling outputs If you have a single stage cooling system leave this set to N If you have a two stage cooling system set to Y to enable 24RC W1 24RH W2 O RS1 RS1 RSC 24C Cooling 24V Fan Cooling stage 1 Cooling stage 2 Remote Sensor 2 Remote Sensor 2 Sensor shield 24VAC Com 24V Heating Aux Heating Change Over Valve Remote Sensor 1 Remote Sensor 1 Sensor shield Remot...

Страница 3: ...N these settings affect HVAC system operation and should only be changed by qualified HVAC service technicians Installer Settings Menu Items Display Lock Options Y or N Default N Y Display LOCKED N Display UNLOCKED Allows you to lock or unlock the thermostat buttons When the buttons are locked you can still access the main menu but you will not be allowed to select any menu options The Installer S...

Страница 4: ... or accept setpoints higher that this maximum Options 40F to 109F 4C 43C Default 90F 32C Min Cool SP Sets the minimum cooling setpoint value Will not ramp or accept setpoints lower than this minimum Options 44F to 113F 6C 45C Default 60F 15C Min Run Time MRT Sets the minimum run time before a heating cooling cycle turns off Sets heating cooling cycle time Prevents rapid cycling Options 1 9 Minutes...

Страница 5: ... 2 Type 3 Type 3 RS2 Location Indoors or Outdoors In Out In Restore Defaults factory defaults Yes or No No Exit no USER SETTINGS Filter Service Submenu Service Interval Disabled 100 4000 hrs 300 Maint Service Submenu Maint Interval Disabled 100 4000 hrs 3000 Screen Timeout to minimized screen 0 20 120 sec 0 0 off will not timeout RH Setpoint 40 70 50 F C Settings F or C F Sensor Calibration Submen...

Страница 6: ...n Auto mode the mode of the last system call will be the setpoint screen displayed Setpoint Push Note that you cannot lower the cooling setpoint below the heating setpoint The thermostat will push the heating setpoint lower if you try to lower the cooling setpoint below the heating setpoint It maintains a 3 degree separation between the heating and cooling setpoint The same is true for raising the...

Страница 7: ...ors Optional Fan Mode Fan Cycler If the Fan Cycler feature is enabled in the Installer Setup the additional fan mode Cycle will be shown in the Fan Mode menu This mode cycles the fan on and off continuously for fresh air ventilation according to the settings in the Installer Setup System Status Indicators When the main thermostat screen is displayed the on screen labels indicate the following Syst...

Страница 8: ... menu item to load the Comfort schedule into the thermostat Confirmation screen will be displayed for Yes No entry Preset EnergyMiser This is a preset schedule with deeper setbacks Select this menu item to load the EnergyMiser schedule into the thermostat Confirmation screen will be displayed for Yes No entry Day Schedule Screen When you select the Heat and Cool Schedule menu item the day schedule...

Страница 9: ...een and the current number of degrees of offset being applied typically 0 If the sensor s actual temp is 75 with 0 degrees of offset and you want it to display 76 then press to add 1 deg and it will indicate 76 in the display with 1 deg offset You can refresh the info on this screen by pressing the right hand blank button When you close this screen it may take a few seconds for the temperature dis...

Страница 10: ...it does not respond immediately due to another call that has recently completed and the MOT delay timer is preventing the system from restarting The MOT delay time can be adjusted in the Installer Settings menu of the thermostat There is a minimum of 5 minutes delay to assure compressor protection Note The MOT status is shown in the thermostat System Status on screen labels DCN 140 02302 01 Page 2...

Страница 11: ...quipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Any chan...