background image

 

1

Chosing the operation mode of the system 

1.1    Mode description 
The  system  have  2  operation  mode,it is  master  mode  and  slaver  mode.in 
master  mode  under  surveillance,if  the  people  enter  into  the  first  sensor 
surveillance  place,it  will  automatically  alarm,if  the  people  enter  into  the 
second sensor surveillance place,it will also automatically spray the pepper. 
in  slaver  mode  under  surveillance,if  the  people  enter  into  surveillance 
place,it will only send the wireless signal to the master and will not alarm,it 
will not spray the pepper also. 
1.2    Mode switch 
On the rear of the top cover,it had 4pcs of circuitry board,one of the largest 
circuitry board is the main control board(see figure 4),if you insert the mode 
switch To M,it is master mode,if you insert to S,it is slaver mode,the default 
mode is master mode.

 

2

Remote controller study 

2.1 The 2 remote controllers with the system already studied,you can use 
directly.If you think 2 remote controllers are not enough,and want buy more 
remote controllers,after you bought it,you need let those remote controllers 
study.otherwise,you can

t control the system(the remote controllers you can 

buy from our distribution)   

   

2.2    Study procedure 

    2.21    Please find the dial switch on the main control circuitry board,it had 2 

dial  code  on  the  dial  switch,it  is  work  and  study  code,  please  dial  work 
code to

1

, ,dail study code to 

N

 ,it indicate the system turn into the study 

mode.meanwhile,you will see the study light will be yellow. 

2.22    Press any button on the remote controller,it will beep 2 times and you 
will see the study light will be green,then the study light will go out and turn 
into  yellow,it  indicate  the  study  is  finished.if  it  is  a  long  beep.  while  in 
studying,and  the  study  light  turn  into  red.then  going  out  and  turn  into 
yellow,it  indicate  the  study  is  failed  or  the  remote  controller  already 
studied.Repeat  again  this  procedure  till  to  finish  the    remote  controller 
which needs to study. 
2.23    After  all  the  remote  controllers  finish  to  study.dail  the  work  code 
to

O

,dail the study mode to

2

,it indicate the system turn into the operation 

mode(the default mode is operation mode),meantime,the study light will go 
out.please press the

OFF

 button on the remote controller.the study light will 

immediately  flash  green.It  indicate  the  study  completely  succeed.if it  flash 
red,it indicate the study is failed,please study again. 

 
 
 
 

Содержание GS901

Страница 1: ...Wireless pepper spray system GS901 Installation Guide Please read this guide carefully and keep it in a safe place ...

Страница 2: ...e the system in the surveillance mode if the unpermissive person enter into the first sensor surveillance area the system will automatically alarm if the unpermissiv e person enter into the second sensor surveillance area the system will automatical ly spray the pepper 3 Pepper in the system introduction Our pepper ingredient used natural strong stimulated ingredient such as purely extractive pepp...

Страница 3: ...ust is made from ABS plastic please take care while in Carrying and installing don t let the unit fall down or kick down 2 while installing please do it strictly according to this manual to avoid the pepper spray out in case of the pepper sprayed on the face please keep calm close the system and pull out the power use the clear water to clean out then clean by 2 soda water after 20 minutes you wil...

Страница 4: ...3 PRODUCT INTRODUCTION CHART Figure 1 Figure 2 ...

Страница 5: ...itive wire into the battery positive head Attention before connected to the battery please put the 2 remote controllers in a safety place to avoid to open the system while in installing Figure 3 Optional function before installation Figure 4 ...

Страница 6: ... can t control the system the remote controllers you can buy from our distribution 2 2 Study procedure 2 21 Please find the dial switch on the main control circuitry board it had 2 dial code on the dial switch it is work and study code please dial work code to 1 dail study code to N it indicate the system turn into the study mode meanwhile you will see the study light will be yellow 2 22 Press any...

Страница 7: ...r bell the carrying capacity of JK port is 10A 250 VA connection mode 1 2 is close 2 3 is open OP PORT is the optical port once the system alarm the optical port will open it can use as driver signal to the other alarm systems the carrying capacity of OP port is 50MA 24V Tips if you feel the above functions don t need to use please don t touch the main control circuitry board direct to the next st...

Страница 8: ...etect it s surveillance place whether have people within 10m if have it will automatically alarm meanwhile open the second sensor to detector whether have people within 1 meters if have it will automatically spray the pepper see figure6 please take care when test Figure6 2 Deactivated alarm and close the system Once the system is in warm up surveillance mode alarm mode Press the OFF button it will...

Страница 9: ...ance mode 4 Alarm stutas Once it alarms the working light will flash every 2 seconds meanwhile open the second sensor to detector whether have people within 1 meters if have it will automatically spray the pepper after 5 minutes it will automatically turn into surveillance mode then close the second sensor of course you can press the OFF button on the remote controller to deactivate WORKING LIGHT ...

Страница 10: ...w to erase the memory 1 Pull out the AC adaptor 2 Use the screwdriver to take the system from the wall open the crust please take care of the screws 3 Finding out the dail switch on the main control circuitry board see figure4 4 Dail the WORK code to O study code to N it will turn into the deactivated status meanwhile the study light will be yellow 5 Press any button on the remote controller it be...

Страница 11: ... alert power 100 dB Detection way Digital infra red pluse and PIR Operation temperature 30 60 The spray distance of the pepper canister 3m The spray speed of the pepper canister 8 5ml s Capacity of the pepper canister 300ml power supply alarm Battery 12V 2Ah adaptor remote control 12V 23A Operation current Surveillance mode 10 mA Alarm status 250 mA Spray the pepper 2A ...

Отзывы: