The same occurs with the sectors when more than 8
are activated at a time.
In the lower one it shows the general outputs ac-
tivated, starting by the pumps (P1234), fertilizers
(F12345678 FC), mixers (M12345678) and the filters.
P
01 03
S
05 06 07 24 33
P1
F124 M12
Filter: 00
The
third screen
indicates the digital functions
activated, whenever they have been configured. The
first ones to be shown at the first line are the irrigation
meters ones (IM1234), the fertilizers meters
(FM12345678), the stop functions (Stop:1234), the
program start ones (Start:12345678) and at the sec-
ond line, the general malfunction function (Gen. Malf.),
the filters differential pressure gauges (Dif. Pre. 1234),
the intrusion alarm one (Alarm), the diesel detector
one (DD) and stop pump (SP:1234).
IM1 3 FM
Stop: 3
Start: 2 7
Gen. Malf. Dif. Pre. 2 Alarm
DD SP1
If volumetric meters for the irrigation or fertiliza-
tion are set in the installation, it will be explained on
the
fourth screen
of the instantaneous flows.
In the first line it shows the irrigation flows. Be-
sides this, if flow control is ordered it can show the
“>” of major or the “<” of minor after the irrigation
meter number, when the instantaneous flow is going
out of the margins. The maximum value that can be
displayed on screen in each format is 650.00 or
6500.0 m
3
/h.
The second line is for the fertilizers instantaneous
flow. When more than four are configured, they will be
shown intermittently in two groups. The maximum
value that can be displayed on screen is 650.00 or
6500.0 L/h.
1=034.40 2<012.77 3=000.00 m
3
/h
F1=000.00 F2=033.21 L/h
When filters cleaning group has been configured,
it will show a screen per group with the information of
the filter which is doing the cleaning and the irrigation
units (minutes or m
3
) missing for the following clean-
ing.
Filters G1, cleaning the 02 (045”)
Units between cleanings: 00262
If a pressure or pH regulation option is installed,
we will see in the first line of the screen the instanta-
neous value of the pH sensor, at its right the reference
requested for the irrigation that is taking place at that
moment, in brackets the injection percentage and
finally, the conductivity sensor value (EC).
In the second line the values correspondent to
the pressure regulation, with the pressure sensor va-
lue, the reference and the injection %.
06.8 pH Ref.= 06.7 pH (045%) 02.1 mS
03.5 bars Ref.= 03.5 bars (075%)
On the last general consultation screen, it informs
about which elements extern to the controller there is
communication established with.
Communication: PC-yes SMS-yes RADIO-no
MicroIsis-yes MONOCABLE-yes
12.2. PROGRAMS CONSULTATION
For each one of the 35 programs, there is an in-
formative screen of the program condition. If it is irri-
gating it will show in the first line next to the program
number the number of the sub-program that is pro-
ceeding, next, if some determining factor are set for
the program it will be shown by the following texts:
o
Non active time
o
Non active period
o
Non active day
o
Conditional stop
o
Stop by priority
o
Time between starts
o
Stop by filter cleaning
o
Stop by fertilizers overlap
o
Waiting for the starting to end
o
OUT OF SERVICE
When the irrigation is ordered by
pressing
at sev-
eral activations, it will show the left ones and the time
missing for the next one:
o
Activations: 03 01:20
Later, if there is a pre-irrigation proceeding in that
moment, it will inform of the units missing to reinitiate
the fertilization.
In the second line, when irrigating, there will be
the units of irrigation and fertilizer still missing to be
applied.
P01-08 Pre.=
00:05
I= 02:18 F1=00:35 F2=01:05
The irrigation units format can vary depending on
the following list:
o
Hours and minutes, 00:00
o
Minutes and seconds, 00’00”
o
Volume in cubic meters , 0000 m3
o
Volume in liters, 0000 L
The fertilizer units one is:
o
Hours and minutes, 00:00
o
Minutes and seconds, 00’00”
o
Volume in liters, 0000 L
o
Volume in deciliters, 0000 dl
o
Volume in centiliters, 0000 cl
o
Application ratio, 000% (press the “MODE”
key in uniform fertilization)