[ values for pH / EC control option ]
[ values for Pressure regulation option ]
6.4. SENSOR PARAMETERS
There are two kinds of sensors, the digital ones to
connect elements which act by contact (differential
pressure gauge, level, meter, etc.) and the analog
ones for sensors which give a proportional signal to
the magnitude that has to be measured (temperature,
sun radiation, humidity, etc.).
Once the “Sensors” option has been chosen at
the “Parameters” menu, the following screen will be
shown to choose the type of sensor to configure.
SENSOR PARAMETERS
Digitals : 1
Analogs : 2
6.4.1. Digital sensors
Each sensor can be assigned a function in order
to act in a pre-determined way when connecting.
Function code number : 00
At the following list the different function codes
and the request it makes to each of them are de-
scribed:
Code
01
:
General Malfunction
Code
02
:
Differential pressure gauge 1
Code
03
:
Differential pressure gauge 2
Code
04
:
Differential pressure gauge 3
Code
05
:
Differential pressure gauge 4
-Detection delay: 030”
Code
06
:
Stop
1
Code
07:
Stop
2
Code
08
:
Stop
3
Code
09
:
Stop
4
- Detection delay: 030”
- Conditional, Temporary, Definitive
- Anomaly Y/N?
Code
10
:
Intrusion alarm
- Detection delay
Code
11
:
Irrigation meter
1, pulses
Code
12
:
Irrigation meter
2, pulses
Code
13
:
Irrigation meter
3, pulses
Code
14
:
Irrigation meter
4, pulses
-Pulse value: 01000 L
-Maximum time between pulses: 240”
Code
15
:
Fertilizer meter
1, pulses
Code
16
:
Fertilizer meter
2, pulses
Code
17
:
Fertilizer meter
3, pulses
Code
18: Fertilizer meter
4, pulses
Code
19
:
Fertilizer meter
5, pulses
Code
20
:
Fertilizer meter
6, pulses
Code
21: Fertilizer meter
7, pulses
Code
22
:
Fertilizer meter
8, pulses
-Pulse value: 0100 cl
-Maximum time between pulses: 200”
Code
23
:
Irrigation meter
1, frequency
Code
24
:
Irrigation meter
2, frequency
Code
25
:
Irrigation meter
3, frequency
Code
26
:
Irrigation meter
4
, frequency
-Cycles per liter: 009.43 Hz
Code
27
:
Fertilizer meter
1, frequency
Code
28
:
Fertilizer meter
2, frequency
Code
29
:
Fertilizer meter
3, frequency
Code
30
:
Fertilizer meter
4, frequency
Code
31
:
Fertilizer meter
5, frequency
Code
32
:
Fertilizer meter
6, frequency
Code
33
:
Fertilizer meter
7, frequency
Code
34
:
Fertilizer meter
8, frequency
-Cycles per centiliter: 128.50 Hz
Code
35
:
Rain gauge
-Liters per pulse: 00.5 L/m
2
Code
36
:
Start
1 of programs
Code
37
:
Start
2 of programs
Code
38
:
Start
3 of programs
Code
39
:
Start
4 of programs
Code
40
:
Start
5 of programs
Code
41
:
Start
6 of programs
Code
42
:
Start
7 of programs
Code
43
:
Start
8 of programs
-Detection delay: 030”
-Stop Y/N : NO
Code
44
:
Diesel detector *
-Detection delay: 030”
Code
45
:
Pump 1 stop
Code
46
:
Pump 2 stop
Code
47
:
Pump 3 stop
Code
48
:
Pump 4 stop
-Detection delay: 030”
*[ only for DIESEL Control option ]
Once the function has been entered, the number
of sensor has to be chosen, to do so, take into ac-
count the chart of the section 4.10.1.
The “Digital input connection” of section 4 has to
be taken into account to deal with the installation and
the connection.
Dig. 7. Stop 2 of sectors
Sensor number : 00000000
For most of the sensors there is a common value
which is the “Detection delay”. This temporization
guarantees the time the input of the sensor has to
keep connected to carry out its function.
The “
General malfunction
” function is used to
stop completely the unit due to the connection of a
security element. It is necessary to have any pump
general output operation in order to have the chance
of acting.